Fachartikel in der Zeitschrift IEEE Transactions on Medical Imaging, 2024-11. Verfasst von Yucheng Lu und 4 weiteren Autor:innen. Hauptthemen laut MEDLINE: Tomography, Spiral Computed, Algorithms. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 77 Literaturangaben. Gefördert von: Korea Medical Device Development Fund Grant, Korea Government.
Abstract (Originalsprache)
Computed tomography (CT) has been used worldwide as a non-invasive test to assist in diagnosis. However, the ionizing nature of X-ray exposure raises concerns about potential health risks such as cancer. The desire for lower radiation doses has driven researchers to improve reconstruction quality. Although previous studies on low-dose computed tomography (LDCT) denoising have demonstrated the effectiveness of learning-based methods, most were developed on the simulated data. However, the real-world scenario differs significantly from the simulation domain, especially when using the multi-slice spiral scanner geometry. This paper proposes a two-stage method for the commercially available multi-slice spiral CT scanners that better exploits the complete reconstruction pipeline for LDCT denoising across different domains. Our approach makes good use of the high redundancy of multi-slice projections and the volumetric reconstructions while leveraging the over-smoothing issue in conventional cascaded frameworks caused by aggressive denoising. The dedicated design also provides a more explicit interpretation of the data flow. Extensive experiments on various datasets showed that the proposed method could remove up to 70% of noise without compromised spatial resolution, while subjective evaluations by two experienced radiologists further supported its superior performance against state-of-the-art methods in clinical practice. Code is available at https://github.com/YCL92/TMD-LDCT.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Förderung
- Korea Medical Device Development Fund Grant
- Korea Government
Zitieren
APA
Lu, Y., Xu, Z., Hyung Choi, M., Kim, J., & Jung, S. W. (2024). Cross-Domain Denoising for Low-Dose Multi-Frame Spiral Computed Tomography. IEEE Transactions on Medical Imaging, 43(11), 3949-3963. https://doi.org/10.1109/tmi.2024.3405024
Vancouver
Lu Y, Xu Z, Hyung Choi M, Kim J, Jung SW. Cross-Domain Denoising for Low-Dose Multi-Frame Spiral Computed Tomography. IEEE Transactions on Medical Imaging. 2024;43(11):3949-3963. doi:10.1109/tmi.2024.3405024
BibTeX
@article{Lu2024,
author = {Lu, Yucheng and Xu, Zhixin and Hyung Choi, Moon and Kim, Jimin and Jung, Seung-Won},
title = {Cross-Domain Denoising for Low-Dose Multi-Frame Spiral Computed Tomography},
journal = {IEEE Transactions on Medical Imaging},
year = {2024},
volume = {43},
number = {11},
pages = {3949--3963},
doi = {10.1109/tmi.2024.3405024}
}