A Phase-to-Phase Current Fault Component Measurement Method for Feeder-Local Detection of Successive Single Phase-to-Ground Faults
IEEE Transactions on Instrumentation and Measurement · 2026 · 75 · 9009115-9009115
DOI: 10.1109/tim.2026.3742014 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2026. Verfasst von Jiawei Yuan und 2 weiteren Autor:innen. Die Arbeit nennt 22 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
Reliable measurement of weak secondary-fault signatures from feeder-terminal current records is challenging under successive single phase-to-ground (SSPG) faults because the secondary-fault component is coupled with and masked by the continuing response of the initial fault. Zero-sequence currents (ZSCs), although widely used for feeder diagnosis, are common-mode quantities observed on both faulty and healthy feeders and can provide limited feeder selectivity under SSPG faults. This article develops a phase-current measurement formulation for SSPG faults that constructs phase-to-phase current fault components (PPCFCs) from existing three-phase feeder-current records. The phase-current composition during the prefault, SSPG-1 fault, and SSPG-2 fault stages is derived to show that interphase differencing suppresses common capacitive-current responses while retaining feeder-local fault-current components. This physical relationship gives the PPCFCs feeder-local selectivity throughout the SSPG fault sequence. An adjacent-cycle rms increment is used to start candidate feeders, and the cosine similarity between the two dominant PPCFCs confirms the opposite-polarity fault-current components and determines the fault phase. PSCAD simulations and full-scale 10-kV field tests demonstrate that the constructed quantities remain observable under various SSPG fault conditions.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Yuan, J., Lin, T., & Jiao, Z. (2026). A Phase-to-Phase Current Fault Component Measurement Method for Feeder-Local Detection of Successive Single Phase-to-Ground Faults. IEEE Transactions on Instrumentation and Measurement, 75, 9009115-9009115. https://doi.org/10.1109/tim.2026.3742014
Vancouver
Yuan J, Lin T, Jiao Z. A Phase-to-Phase Current Fault Component Measurement Method for Feeder-Local Detection of Successive Single Phase-to-Ground Faults. IEEE Transactions on Instrumentation and Measurement. 2026;75:9009115-9009115. doi:10.1109/tim.2026.3742014
BibTeX
@article{Yuan2026,
author = {Yuan, Jiawei and Lin, Taoze and Jiao, Zaibin},
title = {A Phase-to-Phase Current Fault Component Measurement Method for Feeder-Local Detection of Successive Single Phase-to-Ground Faults},
journal = {IEEE Transactions on Instrumentation and Measurement},
year = {2026},
volume = {75},
pages = {9009115--9009115},
doi = {10.1109/tim.2026.3742014}
}
EUVIMED