Orientation-Robust Heart Rate Monitoring Using FMCW Radar via Harmonic Product Spectrum and Fuzzy Logic Inference
IEEE Transactions on Instrumentation and Measurement · 2026 · 75 · 4011213-4011213
DOI: 10.1109/tim.2026.3709438 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2026. Verfasst von Runqi Huo und 4 weiteren Autor:innen. Die Arbeit nennt 42 Literaturangaben.
Abstract (Originalsprache)
Noncontact vital signs monitoring is of significant value for telemedicine and long-term health management. However, existing microwave radar technologies often suffer from heart rate (HR) detection failure in “non-frontal” orientations—such as lateral or posterior views—due to severe signal attenuation and environmental interference. To tackle this challenge, this article proposes an orientation-robust HR estimation scheme. The study first establishes a heartbeat-driven rigid rib kinematic model and derives the frequency offset error to theoretically elucidate the signal attenuation patterns under nonfrontal observations and the failure mechanisms of traditional algorithms. On this basis, a three-stage algorithmic pipeline is constructed: first, principal component analysis (PCA) is utilized to perform multichannel spatial fusion and mitigate orientation-sensitive fading; subsequently, harmonic product spectrum (HPS) method is employed to perform harmonic structural focusing and isolate the HR search band (HRSB); finally, a fuzzy logic mechanism is introduced to perform multidimensional evaluation of the “structural integrity” and “energy intensity” of harmonic paths, achieving precise locking of the true HR. Experimental validation involving eight subjects across multiple postures and angles demonstrates the robust performance of the proposed method across various scenarios. Even in the most challenging lateral standing scenario, its accuracy and the continuity of the HR estimation trajectory remain significantly superior to traditional spectral analysis and modal decomposition methods. This study provides a theoretical basis for overcoming the orientation bottleneck in noncontact monitoring and establishes a technical foundation for all-scenario, multiposture intelligent health monitoring in complex environments.
Zitieren
APA
Huo, R., Yuan, T., Ren, A., Kuo, Y., & Xie, D. (2026). Orientation-Robust Heart Rate Monitoring Using FMCW Radar via Harmonic Product Spectrum and Fuzzy Logic Inference. IEEE Transactions on Instrumentation and Measurement, 75, 4011213-4011213. https://doi.org/10.1109/tim.2026.3709438
Vancouver
Huo R, Yuan T, Ren A, Kuo Y, Xie D. Orientation-Robust Heart Rate Monitoring Using FMCW Radar via Harmonic Product Spectrum and Fuzzy Logic Inference. IEEE Transactions on Instrumentation and Measurement. 2026;75:4011213-4011213. doi:10.1109/tim.2026.3709438
BibTeX
@article{Huo2026,
author = {Huo, Runqi and Yuan, Tongyang and Ren, Aifeng and Kuo, Youyu and Xie, Dihong},
title = {Orientation-Robust Heart Rate Monitoring Using FMCW Radar via Harmonic Product Spectrum and Fuzzy Logic Inference},
journal = {IEEE Transactions on Instrumentation and Measurement},
year = {2026},
volume = {75},
pages = {4011213--4011213},
doi = {10.1109/tim.2026.3709438}
}
EUVIMED