EUVIMEDEUVIMED entdecken
Crossref

Health-Radar: Noncontact Multitarget Heart Rate Variability Detection Using FMCW Radar

Zhimeng Xu, Tao Ye, Liangqin Chen, Yueming Gao, Zhizhang Chen

IEEE Sensors Journal · 01.01.2025 · 25 (1) · 405-418

DOI: 10.1109/jsen.2024.3494755 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Sensors Journal, erschienen am 01.01.2025. Verfasst von Zhimeng Xu und 4 weiteren Autor:innen. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 44 Literaturangaben. Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China, Major Program of the Department of Science and Technology of Fujian Province.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Heart rate variability (HRV), indicating the variation in intervals between consecutive heartbeats, is a crucial physiological indicator of human health. However, detecting HRV using frequency-modulated continuous-wave (FMCW) radar is highly susceptible to interference from respiration, minor body movements, and environmental noise, especially in multitarget scenarios. To address these challenges, we propose the Health-Radar system, which comprises three functional modules. In the target detection module, the system accurately identifies the number and locations of targets. In the phase extraction module, the signal undergoes dc offset calibration to extract the chest displacement signals. In the heartbeat signal extraction module, we introduce Health-VMD, an adaptive parameter variational mode decomposition (VMD) method. This method optimizes the VMD parameters using an improved grasshopper optimization algorithm (GOA) and accurately extracts vital sign signals from chest displacement signals to estimate HRV. In addition, we propose a novel objective function, composed of permutation entropy, mutual information, and energy loss rate (PME), specifically designed for vital sign extraction. Experiments with multiple participants in various scenarios demonstrated that the designed system can accurately identify different targets and detect HRV with high precision. The root-mean-square error (RMSE) of the detected interbeat intervals (IBIs) is 29.72 ms, the RMSE of the standard deviation of NN intervals (SDNN) is 4.1 ms, and the RMSE of the root mean square of successive differences (RMSSD) is 18.61 ms, outperforming existing methods.

Förderung

  • National Key Research and Development Program of China
  • National Natural Science Foundation of China
  • Major Program of the Department of Science and Technology of Fujian Province
  • Industry-University-Research Collaboration Project of Fujian Province

Zitieren

APA

Xu, Z., Ye, T., Chen, L., Gao, Y., & Chen, Z. (2025). Health-Radar: Noncontact Multitarget Heart Rate Variability Detection Using FMCW Radar. IEEE Sensors Journal, 25(1), 405-418. https://doi.org/10.1109/jsen.2024.3494755

Vancouver

Xu Z, Ye T, Chen L, Gao Y, Chen Z. Health-Radar: Noncontact Multitarget Heart Rate Variability Detection Using FMCW Radar. IEEE Sensors Journal. 2025;25(1):405-418. doi:10.1109/jsen.2024.3494755

BibTeX
@article{Xu2025,
  author = {Xu, Zhimeng and Ye, Tao and Chen, Liangqin and Gao, Yueming and Chen, Zhizhang},
  title = {Health-Radar: Noncontact Multitarget Heart Rate Variability Detection Using FMCW Radar},
  journal = {IEEE Sensors Journal},
  year = {2025},
  volume = {25},
  number = {1},
  pages = {405--418},
  doi = {10.1109/jsen.2024.3494755}
}
Kostenlos starten →