EUVIMEDEUVIMED entdecken
Crossref

Accurate Assessment of Oxide Film Thickness on Complex Fuel Spacer Grids Under Inadequate Alignment Conditions

Jingqi Jiao, Jiarui Feng, Yaowen Liu, Ming Li, Chaofeng Ye

IEEE Transactions on Instrumentation and Measurement · 2026 · 75 · 6004210-6004210

DOI: 10.1109/tim.2026.3706165 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2026. Verfasst von Jingqi Jiao und 4 weiteren Autor:innen. Die Arbeit nennt 30 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate assessment of oxide film thickness on nuclear fuel components is essential for ensuring operational safety and performance. While eddy current testing (ECT) has been widely applied to oxide thickness evaluation on fuel claddings with regular cylindrical geometries, its application to fuel spacer grids remains challenging due to complex structural features and unavoidable probe misalignment during inspection, significantly constraining measurement accuracy and efficiency. This article presents a novel ECT-based measurement with auxiliary strain-sensor-assisted compensation methodology for the accurate evaluation of oxide film thickness on fuel spacer grids under inadequate alignment conditions. A feature extraction strategy is first developed by exploiting the geometric and structural characteristics of spacer grids, enabling effective separation of oxide-related information from strong structural responses. Furthermore, a regression-based compensation model is proposed to alleviate tilt-induced signal drift, effectively decoupling the nonlinear relationship between oxide layer thickness and tilt. Experimental results demonstrate that the proposed approach achieves a mean absolute error (MAE) of $1.1~\mu $ m, a root mean square error (RMSE) of $1.6~\mu $ m, and a coefficient of determination of 0.998 throughout a tilt angle range of 0.0°–12.8°, therefore greatly enhancing measurement resilience and accuracy. The proposed method enables reliable oxide film thickness assessment on spacer grids without strict alignment constraints, offering a practical and data-efficient solution for in-service nuclear fuel inspection.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Jiao, J., Feng, J., Liu, Y., Li, M., & Ye, C. (2026). Accurate Assessment of Oxide Film Thickness on Complex Fuel Spacer Grids Under Inadequate Alignment Conditions. IEEE Transactions on Instrumentation and Measurement, 75, 6004210-6004210. https://doi.org/10.1109/tim.2026.3706165

Vancouver

Jiao J, Feng J, Liu Y, Li M, Ye C. Accurate Assessment of Oxide Film Thickness on Complex Fuel Spacer Grids Under Inadequate Alignment Conditions. IEEE Transactions on Instrumentation and Measurement. 2026;75:6004210-6004210. doi:10.1109/tim.2026.3706165

BibTeX
@article{Jiao2026,
  author = {Jiao, Jingqi and Feng, Jiarui and Liu, Yaowen and Li, Ming and Ye, Chaofeng},
  title = {Accurate Assessment of Oxide Film Thickness on Complex Fuel Spacer Grids Under Inadequate Alignment Conditions},
  journal = {IEEE Transactions on Instrumentation and Measurement},
  year = {2026},
  volume = {75},
  pages = {6004210--6004210},
  doi = {10.1109/tim.2026.3706165}
}
Kostenlos starten →