Embedded Fiber-Optic Sensor for In Situ Leakage Magnetic Field Detection in Power Transformer

Yukun Wang, Guoming Ma, Junting Ji, Fan Yang, Biqian Xu, Houxian Du, Pengfei Wang

IEEE Transactions on Instrumentation and Measurement · 2026 · 75 · 9525510-9525510

DOI: 10.1109/tim.2026.3704186 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Instrumentation and Measurement, 2026. Verfasst von Yukun Wang und 6 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: Science and Technology Project of SGCC.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Internal leakage magnetic field measurement in power transformers requires compact, electrically passive, and electromagnetically immune sensing devices that can be installed inside transformer structures. To address these limitations, this work proposes a fiber-optic magnetic field sensor based on the Faraday magneto-optical effect. The sensing probe is constructed by fixing a Bi:yttrium iron garnet (YIG) magneto-optical crystal inside a cylindrical glass tube and integrating it with polarization-maintaining collimators, forming a compact in-line structure suitable for transformer embedding. A polarization-division detection topology is developed to realize real-time reconstruction of the polarization-plane rotation angle. The performance of the proposed sensing system was experimentally calibrated. Under power-frequency magnetic fields from 0 to 6.2 mT, the sensor exhibited a magnetic field sensitivity of 56.1 mrad/mT and an experimentally verified detection limit below $6~\mu $ T. It also demonstrated a relatively flat frequency response from 10 Hz to 1 kHz, as well as low hysteresis and repeatability characteristics. Finally, an embedded installation method was implemented in a 35-kV transformer model with preset winding deformation. Under rated current, the sensor successfully measured the leakage magnetic field at the deformed winding end and captured waveform distortion with observable harmonic components. These results demonstrate the feasibility of the proposed sensor for high-sensitivity and transformer-embedded leakage magnetic field measurement, while the interpretation and classification of specific winding fault types remain beyond the scope of this work.

Förderung

  • Science and Technology Project of SGCC

Zitieren

APA

Wang, Y., Ma, G., Ji, J., Yang, F., Xu, B., Du, H., & Wang, P. (2026). Embedded Fiber-Optic Sensor for In Situ Leakage Magnetic Field Detection in Power Transformer. IEEE Transactions on Instrumentation and Measurement, 75, 9525510-9525510. https://doi.org/10.1109/tim.2026.3704186

Vancouver

Wang Y, Ma G, Ji J, Yang F, Xu B, Du H, et al. Embedded Fiber-Optic Sensor for In Situ Leakage Magnetic Field Detection in Power Transformer. IEEE Transactions on Instrumentation and Measurement. 2026;75:9525510-9525510. doi:10.1109/tim.2026.3704186

BibTeX
@article{Wang2026,
  author = {Wang, Yukun and Ma, Guoming and Ji, Junting and Yang, Fan and Xu, Biqian and Du, Houxian and Wang, Pengfei},
  title = {Embedded Fiber-Optic Sensor for In Situ Leakage Magnetic Field Detection in Power Transformer},
  journal = {IEEE Transactions on Instrumentation and Measurement},
  year = {2026},
  volume = {75},
  pages = {9525510--9525510},
  doi = {10.1109/tim.2026.3704186}
}