A Gold-Diaphragm Fabry–Pérot Fiber-Optic Ultrasonic Sensor for Partial Discharge Detection in Transformer Oil
IEEE Sensors Journal · 2026-08 · 26 (15) · 22596-22605
DOI: 10.1109/jsen.2026.3707398 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Sensors Journal, 2026-08. Verfasst von Xueman Hou und 7 weiteren Autor:innen. Die Arbeit nennt 44 Literaturangaben. Gefördert von: Science and Technology Project of State Grid Corporation of China (SGCC).
Abstract (Originalsprache)
Ultrasonic detection of partial discharge (PD) in transformer oil is important for insulation assessment and early fault warning in power transformers. To address the tradeoff among fabrication complexity, cost, and detection sensitivity in existing fiber-optic Fabry–Pérot (F–P) sensors for PD ultrasonic detection, a high-sensitivity fiber-optic F–P ultrasonic sensor based on a gold diaphragm was proposed. By enlarging the diaphragm diameter and employing a gold diaphragm with a low Young’s modulus and a high Poisson’s ratio as the acoustic-sensitive element, the acoustic response sensitivity was improved. A low-cost fabrication scheme was developed by combining electron-beam evaporation with a sacrificial-layer-assisted transfer strategy, enabling stable transfer of the gold diaphragm onto the end face of a ceramic sleeve without hollow-core fiber (HCF) splicing or an additional supporting layer. Performance evaluations were carried out in transformer oil. The results indicated that the proposed sensor achieved a sensitivity of 940 nm/kPa and a minimum detectable acoustic pressure of 7.1 mPa while maintaining high linearity over the tested pressure range up to 60 Pa (R ${}^{\mathbf {{2}}} =0.995$ ). A 10-h continuous monitoring test demonstrated good signal stability, and after ten thermal cycles between $20~^{\circ }$ C and $80~^{\circ }$ C, the sensitivity decreased by about 8% while the linearity remained high. In a transformer oil tank with a needle–plane defect model, the sensor successfully detected PD-induced ultrasonic signals, and its phase amplitude increased with PD magnitude. These results demonstrate its feasibility for online PD monitoring in oil-immersed transformers.
Förderung
- Science and Technology Project of State Grid Corporation of China (SGCC)
Zitieren
APA
Hou, X., Wang, Y., Xu, B., Liu, H., Du, H., Yu, H., Wang, Y., & Ma, G. (2026). A Gold-Diaphragm Fabry–Pérot Fiber-Optic Ultrasonic Sensor for Partial Discharge Detection in Transformer Oil. IEEE Sensors Journal, 26(15), 22596-22605. https://doi.org/10.1109/jsen.2026.3707398
Vancouver
Hou X, Wang Y, Xu B, Liu H, Du H, Yu H, et al. A Gold-Diaphragm Fabry–Pérot Fiber-Optic Ultrasonic Sensor for Partial Discharge Detection in Transformer Oil. IEEE Sensors Journal. 2026;26(15):22596-22605. doi:10.1109/jsen.2026.3707398
BibTeX
@article{Hou2026,
author = {Hou, Xueman and Wang, Yukun and Xu, Biqian and Liu, Hao and Du, Houxian and Yu, Hua and Wang, Yuan and Ma, Guoming},
title = {A Gold-Diaphragm Fabry–Pérot Fiber-Optic Ultrasonic Sensor for Partial Discharge Detection in Transformer Oil},
journal = {IEEE Sensors Journal},
year = {2026},
volume = {26},
number = {15},
pages = {22596--22605},
doi = {10.1109/jsen.2026.3707398}
}
EUVIMED