Offline Quantitative Evaluation of Electrical Machine Insulation Through Common-Mode Impedance Resonance Frequency Perturbation
IEEE Transactions on Industrial Electronics · 2024-08 · 71 (8) · 9687-9697
DOI: 10.1109/tie.2023.3323738 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Industrial Electronics, 2024-08. Verfasst von Hao Li und 3 weiteren Autor:innen. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Shanghai, Shanghai Rising-Star Program.
Abstract (Originalsprache)
Identifying high-frequency common-mode parameters is crucial for assessing the insulation health of inverter-fed machine systems. However, this task presents significant challenges due to the frequency-dependent effects on winding inductance and resistance. To overcome these difficulties, this article proposes a method for common-mode parameter identification based on resonance frequency perturbation. First, the common-mode resonant frequency is marginally adjusted around the initial value by introducing a series of minor capacitors between the machine terminals (either line-end or neutral-point) and the ground. Subsequently, the frequency-independent capacitances are computed by resolving the resonance frequency minor perturbation equations, utilizing the particle swarm optimization algorithm. Lastly, frequency-dependent inductance and resistance are identified via resonance frequency sweeping. Experimental work was conducted on a 380 V/3 kW induction machine using both star and delta connections. Despite the frequency-dependent inductance and resistance, the parasitic capacitances of the stator winding were accurately extracted. This allows for a quantitative health evaluation of turn and groundwall insulation, with a relative error of approximately 1%.
Förderung
- National Natural Science Foundation of China
- Natural Science Foundation of Shanghai
- Shanghai Rising-Star Program
Zitieren
APA
Li, H., Chen, J., Xiang, D., & Cheng, R. (2024). Offline Quantitative Evaluation of Electrical Machine Insulation Through Common-Mode Impedance Resonance Frequency Perturbation. IEEE Transactions on Industrial Electronics, 71(8), 9687-9697. https://doi.org/10.1109/tie.2023.3323738
Vancouver
Li H, Chen J, Xiang D, Cheng R. Offline Quantitative Evaluation of Electrical Machine Insulation Through Common-Mode Impedance Resonance Frequency Perturbation. IEEE Transactions on Industrial Electronics. 2024;71(8):9687-9697. doi:10.1109/tie.2023.3323738
BibTeX
@article{Li2024,
author = {Li, Hao and Chen, Jinyu and Xiang, Dawei and Cheng, Ruijunjie},
title = {Offline Quantitative Evaluation of Electrical Machine Insulation Through Common-Mode Impedance Resonance Frequency Perturbation},
journal = {IEEE Transactions on Industrial Electronics},
year = {2024},
volume = {71},
number = {8},
pages = {9687--9697},
doi = {10.1109/tie.2023.3323738}
}
EUVIMED