EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Automated Electrorotation System for High-Throughput Dielectric Cell Characterization

Samuele Moscato, Andrea Ballo, Pasquale Memmolo, Paolo Bonacci, Nicolo Musso, Maide Bucolo, Massimo Camarda

IEEE Transactions on Biomedical Engineering · 2026-05 · 73 (5) · 1890-1899

DOI: 10.1109/tbme.2025.3617496 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Biomedical Engineering, 2026-05. Verfasst von Samuele Moscato und 6 weiteren Autor:innen. Hauptthemen laut MEDLINE: Equipment Design, High-Throughput Screening Assays. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Commission, SAMOTHRACE.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: This work presents ROT-QSG, a compact, automated, and user-friendly electrorotation system for label-free dielectric characterization of biological cells, enabling applications in disease diagnosis, drug discovery, and personalized medicine. METHODS: The ROT-QSG system consists of three main components: (1) a custom electronic device-Quadrature Signal Generator (QSG); (2) a specifically designed electrorotation chip-ROT-chip; and (3) a dedicated image processing algorithm-Pixel Intensity (PxI)-which enables automatic, operator-independent extraction of cell rotation data. Electrorotation allows the dielectric characterization of cells by analyzing their rotational response to varying electric field frequencies, generating the rotation-frequency spectrum (ROT-spectrum). To ensure high consistency and repeatability, the entire experimental workflow-from signal generation to spectrum extraction-has been fully automated through a dedicated experimental control algorithm. RESULTS: The system was validated by analyzing three immortalized cell lines (CaCo-2, CCD-841, and OPM2), from which ROT spectra and corresponding cell membrane capacitance values were successfully extracted. CONCLUSION: The comparative study revealed clear differences in membrane capacitance among the three cell types, confirming the system's capability to detect meaningful dielectric variations. The repeatability of measurements within each cell line and the observed distinct spectral differences between the cell lines demonstrate its sensitivity to variations in membrane morphology and structural organization. SIGNIFICANCE: The system, designed with a strong focus on integration, automation, and ease of use in biological settings, has the potential to enhance dielectric characterization across a wide range of cell types, contributing to a deeper understanding of cellular functions and disease mechanisms.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Equipment DesignHigh-Throughput Screening AssaysAutomationElectric ImpedanceAlgorithmsHumansCell LineSignal Processing, Computer-AssistedImage Processing, Computer-Assisted

Förderung

  • European Commission
  • SAMOTHRACE

Zitieren

APA

Moscato, S., Ballo, A., Memmolo, P., Bonacci, P., Musso, N., Bucolo, M., & Camarda, M. (2026). Automated Electrorotation System for High-Throughput Dielectric Cell Characterization. IEEE Transactions on Biomedical Engineering, 73(5), 1890-1899. https://doi.org/10.1109/tbme.2025.3617496

Vancouver

Moscato S, Ballo A, Memmolo P, Bonacci P, Musso N, Bucolo M, et al. Automated Electrorotation System for High-Throughput Dielectric Cell Characterization. IEEE Transactions on Biomedical Engineering. 2026;73(5):1890-1899. doi:10.1109/tbme.2025.3617496

BibTeX
@article{Moscato2026,
  author = {Moscato, Samuele and Ballo, Andrea and Memmolo, Pasquale and Bonacci, Paolo and Musso, Nicolo and Bucolo, Maide and Camarda, Massimo},
  title = {Automated Electrorotation System for High-Throughput Dielectric Cell Characterization},
  journal = {IEEE Transactions on Biomedical Engineering},
  year = {2026},
  volume = {73},
  number = {5},
  pages = {1890--1899},
  doi = {10.1109/tbme.2025.3617496}
}
Kostenlos starten →