Force Measurements to Advance the Design and Implantation of CMOS-Based Neural Probes
IEEE Transactions on Biomedical Engineering · 2025
DOI: 10.1109/tbme.2024.3519763 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Biomedical Engineering, 2025. Verfasst von Alberto Perna und 3 weiteren Autor:innen. Hauptthemen laut MEDLINE: Electrodes, Implanted, Brain-Computer Interfaces. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Union – NextGenerationEU, HORIZON EUROPE European Innovation Council, Crossbrain project.
Abstract (Originalsprache)
OBJECTIVE: Tissue penetrating active neural probes provide large and densely packed microelectrode arrays for the fine-grained investigation of brain circuits and for advancing brain-machine interfaces (BMIs). To improve the electrical interfacing performances of such stiff silicon devices, which typically elicit a vigorous foreign body reaction (FBR), here we perform insertion force measurements and derive probe layout and implantation procedure optimizations. METHODS: We performed in-vivo insertion force measurements to evaluate the impact of probe design and implantation speed on mechanically induced trauma and iatrogenic injury. Because acute damage constitutes the initial trigger of FBR, these experiments allow to characterize and minimize device invasiveness. RESULTS: Probe sharpness outweighs cross-sectional dimensions during the dimpling stage of the implantation, when the device compresses the brain before penetration. Insertion speed does not display a major effect on dimpling magnitude. A slow speed, however, significantly increases dimpling duration. CONCLUSION: It is crucial to use sharp devices to reduce mechanical and ischemic damage. Although slow insertion speeds typically improve the quality of acute electrophysiological recordings, we show that slow speeds should only be used upon penetration in the brain parenchyma and not during the dimpling stage. A closed-loop implantation procedure can be used to set the appropriate speed in the different insertion stages. SIGNIFICANCE: We provide new evidence on the impact of probe layout and insertion speed on insertion force, with implications on the design and implantation procedure for minimally invasive CMOS neural probes. A novel closed-loop methodology to optimize device implantation and reduce FBR is proposed.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Förderung
- European Union – NextGenerationEU
- HORIZON EUROPE European Innovation Council
- Crossbrain project
Zitieren
APA
Perna, A., Orban, G., Berdondini, L., & Ribeiro, J. F. (2025). Force Measurements to Advance the Design and Implantation of CMOS-Based Neural Probes. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2024.3519763
Vancouver
Perna A, Orban G, Berdondini L, Ribeiro JF. Force Measurements to Advance the Design and Implantation of CMOS-Based Neural Probes. IEEE Transactions on Biomedical Engineering. 2025. doi:10.1109/tbme.2024.3519763
BibTeX
@article{Perna2025,
author = {Perna, Alberto and Orban, Gabor and Berdondini, Luca and Ribeiro, Joao F},
title = {Force Measurements to Advance the Design and Implantation of CMOS-Based Neural Probes},
journal = {IEEE Transactions on Biomedical Engineering},
year = {2025},
doi = {10.1109/tbme.2024.3519763}
}
EUVIMED