EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Systematic evaluation of surgical insertion of flexible neural probe arrays into deeper brain targets using length modulation methods

Yingyi Gao iD, Zhouxiao Lu iD, Xuechun Wang iD, Zihan Jin iD, Alberto Esteban-Linares iD, Jeffery Guo, Huijing Xu iD, Kee Scholten iD, Dong Song iD, Ellis Meng iD

Journal of Neural Engineering · 2026

DOI: 10.1088/1741-2552/ae385c ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Neural Engineering, 2026. Verfasst von Yingyi Gao und 9 weiteren Autor:innen. Beteiligte Einrichtung: Alfred E. Mann Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, United States of America. Hauptthemen laut MEDLINE: Electrodes, Implanted, Brain. Die Arbeit nennt 82 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NINDS NIH HHS, University of Southern California Annenberg Fellowship, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective . Penetrating polymer-based microelectrode arrays (pMEAs) offer the potential for long term high-quality electrophysiological recordings of dynamic neural activity. Compared to rigid metal wire and silicon MEAs, improved device-tissue interface stability has been reported. However, accurate surgical placement of long, thin shanks in deeper brain regions is challenging as flexibility is achieved at the expense of axial stiffness. This study systematically evaluates then compares two pMEA placement strategies—dissolvable dip coating and molded brace, both with bare, exposed pMEA tips—to address the need for consistent, reliable, and accurate surgical targeting. These methods were selected based on the criteria of ease of fabrication, surgical feasibility, and mechanical performance. Approach . Sham (mechanical model with no electrodes) and fully functional pMEAs with shanks up to 5.5 mm long were fabricated and then modified using biodegradable polyethylene glycol (PEG) to support implantation. PEG was applied to shanks by motorized dip coating or a mechanical mold. Dissolution time and insertion in agarose gel brain models and rat cortex were evaluated followed by targeting of dip coated pMEAs to the rat hippocampus. Main results . Dip coating at high withdrawal speeds achieved uniform coating on shanks. Both strategies yielded similar critical buckling forces and insertion forces for single shank and arrayed pMEAs. Dip coated pMEAs were successfully placed in hippocampal regions without severe tissue damage as confirmed by histology and recordings obtained. Significance . Dip coating is a simpler method to prepare pMEAs for surgical targeting of deep brain regions compared to the bracing technique, as it does not require both a specialized mold and application process. This work provides a guide for researchers using single or multi-shank pMEAs to an accessible insertion strategy for implanting into deep brain regions in rodents and other small animal models.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Electrodes, ImplantedBrainAnimalsRatsMicroelectrodesRats, Sprague-DawleyMaleEquipment Design

Stichwörter der Autor:innen

flexible microelectrode arrayflexible neural probesneural probe insertion

Autor:innen und Institutionen

  • Alfred E. Mann Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, United States of America.
  • College of Information and Electrical Engineering, China Agricultural University, Beijing, People's Republic of China.
  • Elegen Corp, San Carlos, CA, United States of America.
  • Department of Mechanical Engineering, Purdue University, West Lafayette, IN, United States of America.
  • Bioventus, Valencia, CA, United States of America.
  • Department of Neurological Surgery, University of Southern California, Los Angeles, CA, United States of America.

ORCID-Profile: Yingyi Gao, Zhouxiao Lu, Xuechun Wang, Zihan Jin, Alberto Esteban-Linares, Huijing Xu, Kee Scholten, Dong Song, Ellis Meng

Förderung

  • NINDS NIH HHS
  • University of Southern California Annenberg Fellowship
  • National Institutes of Health

Zitieren

APA

Gao, Y., Lu, Z., Wang, X., Jin, Z., Esteban-Linares, A., Guo, J., Xu, H., Scholten, K., Song, D., & Meng, E. (2026). Systematic evaluation of surgical insertion of flexible neural probe arrays into deeper brain targets using length modulation methods. Journal of Neural Engineering. https://doi.org/10.1088/1741-2552/ae385c

Vancouver

Gao Y, Lu Z, Wang X, Jin Z, Esteban-Linares A, Guo J, et al. Systematic evaluation of surgical insertion of flexible neural probe arrays into deeper brain targets using length modulation methods. Journal of Neural Engineering. 2026. doi:10.1088/1741-2552/ae385c

BibTeX
@article{Gao2026,
  author = {Gao, Yingyi and Lu, Zhouxiao and Wang, Xuechun and Jin, Zihan and Esteban-Linares, Alberto and Guo, Jeffery and Xu, Huijing and Scholten, Kee and Song, Dong and Meng, Ellis},
  title = {Systematic evaluation of surgical insertion of flexible neural probe arrays into deeper brain targets using length modulation methods},
  journal = {Journal of Neural Engineering},
  year = {2026},
  doi = {10.1088/1741-2552/ae385c}
}
Kostenlos starten →