Muscle Activity and Biomechanics While Descending a Staircase After Total Knee Arthroplasty: A Study Comparing Different Posterior Stabilized and Medial Ball-and-Socket Designs
The Journal of Arthroplasty · 2024
DOI: 10.1016/j.arth.2024.06.022 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift The Journal of Arthroplasty, 2024. Verfasst von Erik Kowalski und 4 weiteren Autor:innen. Beteiligte Einrichtung: Human Movement Biomechanics Laboratory, University of Ottawa, Ottawa, Canada. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Knee Joint, Knee Prosthesis, Muscle, Skeletal. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: MicroPort Scientific Corp.
Abstract (Originalsprache)
BACKGROUND: Many patients report more difficulty when descending stairs compared to level walking after total knee arthroplasty (TKA). Different implant designs can affect knee biomechanics and muscle activity during gait, but their effect during stair descent is unclear. The purpose of this study was to evaluate knee biomechanics and muscle activations of quadriceps, hamstrings, and gastrocnemius muscles during a stair descent task in patients who underwent TKA with either a posterior stabilized (PS) or medial ball-and-socket (MBS) implant and to compare them to a group of healthy controls. METHODS: There were 28 TKA patients who were randomized to either an MBS (n = 14) or PS (n = 14) implant and were compared with 14 controls. Patients visited the biomechanics lab approximately 12 months after TKA, where knee biomechanics and muscle activity were measured as they descended a 3-step staircase. RESULTS: Compared to the MBS and control groups, the PS group descended the stairs with a reduced knee flexion angle and greater hamstring muscle activation throughout single limb support. Knee joint moments and power were similar between the MBS and PS groups, but neither reached the level of the control group. CONCLUSIONS: Lower knee flexion angles and increased hamstring muscle activity indicated that the PS group descended the stairs with a stiffer knee gait pattern than the MBS group. The MBS implant design may provide additional stability as patients require less muscle activity than the PS group.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Human Movement Biomechanics Laboratory, University of Ottawa, Ottawa, Canada.
- Human Movement Biomechanics Laboratory, University of Ottawa, Ottawa, Canada; Laboratory of Applied Biomechanics, State University of Londrina, Londrina, Brazil.
- Division of Orthopedic Surgery, The Ottawa Hospital, Ottawa, Canada.
- Human Movement Biomechanics Laboratory, University of Ottawa, Ottawa, Canada; Division of Orthopedic Surgery, The Ottawa Hospital, Ottawa, Canada.
Förderung
- MicroPort Scientific Corp
Zitieren
APA
Kowalski, E., Pelegrinelli, A. R. M., Ryan, N., Dervin, G., & Lamontagne, M. (2024). Muscle Activity and Biomechanics While Descending a Staircase After Total Knee Arthroplasty: A Study Comparing Different Posterior Stabilized and Medial Ball-and-Socket Designs. The Journal of Arthroplasty. https://doi.org/10.1016/j.arth.2024.06.022
Vancouver
Kowalski E, Pelegrinelli ARM, Ryan N, Dervin G, Lamontagne M. Muscle Activity and Biomechanics While Descending a Staircase After Total Knee Arthroplasty: A Study Comparing Different Posterior Stabilized and Medial Ball-and-Socket Designs. The Journal of Arthroplasty. 2024. doi:10.1016/j.arth.2024.06.022
BibTeX
@article{Kowalski2024,
author = {Kowalski, Erik and Pelegrinelli, Alexandre R M and Ryan, Nicholas and Dervin, Geoffrey and Lamontagne, Mario},
title = {Muscle Activity and Biomechanics While Descending a Staircase After Total Knee Arthroplasty: A Study Comparing Different Posterior Stabilized and Medial Ball-and-Socket Designs},
journal = {The Journal of Arthroplasty},
year = {2024},
doi = {10.1016/j.arth.2024.06.022}
}
EUVIMED