EUVIMEDEUVIMED entdecken
Open Access

Mathematical Modeling of Oscillometric Blood Pressure Measurement: A Complete, Reduced Oscillogram Model

Vishaal Dhamotharan, Anand Chandrasekhar, Hao-Min Cheng, Chen-Huan Chen, Shih-Hsien Sung, Cederick Landry, Jin-Oh Hahn, Aman Mahajan, Sanjeev G Shroff, Ramakrishna Mukkamala

IEEE Transactions on Biomedical Engineering · 2023-02 · 70 (2) · 715-722

DOI: 10.1109/tbme.2022.3201433 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Biomedical Engineering, 2023-02. Verfasst von Vishaal Dhamotharan und 9 weiteren Autor:innen. Hauptthemen laut MEDLINE: Blood Pressure Determination, Arterial Pressure. Die Arbeit wurde bisher 27-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NHLBI NIH HHS, NIH.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: Oscillogram modeling is a powerful tool for understanding and advancing popular oscillometric blood pressure (BP) measurement. A reduced oscillogram model relating cuff pressure oscillation amplitude ( ∆O) to external cuff pressure of the artery ( Pe) is: [Formula: see text], where g(P) is the arterial compliance versus transmural pressure ( P) curve, Ps and Pd are systolic and diastolic BP, and k is the reciprocal of the cuff compliance. The objective was to determine an optimal functional form for the arterial compliance curve. METHODS: Eight prospective, three-parameter functions of the brachial artery compliance curve were compared. The study data included oscillometric arm cuff pressure waveforms and invasive brachial BP from 122 patients covering a 20-120 mmHg pulse pressure range. The oscillogram measurements were constructed from the cuff pressure waveforms. Reduced oscillogram models, inputted with measured systolic and diastolic BP and each parametric brachial artery compliance curve function, were optimally fitted to the oscillogram measurements in the least squares sense. RESULTS: An exponential-linear function yielded as good or better model fits compared to the other functions, with errors of 7.9±0.3 and 5.1±0.2% for tail-trimmed and lower half-trimmed oscillogram measurements. Importantly, this function was also the most tractable mathematically. CONCLUSION: A three-parameter exponential-linear function is an optimal form for the arterial compliance curve in the reduced oscillogram model and may thus serve as the standard function for this model henceforth. SIGNIFICANCE: The complete, reduced oscillogram model determined herein can potentially improve oscillometric BP measurement accuracy while advancing foundational knowledge.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood Pressure DeterminationArterial PressureHumansBlood PressureProspective StudiesBrachial Artery

Förderung

  • NHLBI NIH HHS
  • NIH

Zitieren

APA

Dhamotharan, V., Chandrasekhar, A., Cheng, H. M., Chen, C. H., Sung, S. H., Landry, C., Hahn, J. O., Mahajan, A., Shroff, S. G., & Mukkamala, R. (2023). Mathematical Modeling of Oscillometric Blood Pressure Measurement: A Complete, Reduced Oscillogram Model. IEEE Transactions on Biomedical Engineering, 70(2), 715-722. https://doi.org/10.1109/tbme.2022.3201433

Vancouver

Dhamotharan V, Chandrasekhar A, Cheng HM, Chen CH, Sung SH, Landry C, et al. Mathematical Modeling of Oscillometric Blood Pressure Measurement: A Complete, Reduced Oscillogram Model. IEEE Transactions on Biomedical Engineering. 2023;70(2):715-722. doi:10.1109/tbme.2022.3201433

BibTeX
@article{Dhamotharan2023,
  author = {Dhamotharan, Vishaal and Chandrasekhar, Anand and Cheng, Hao-Min and Chen, Chen-Huan and Sung, Shih-Hsien and Landry, Cederick and Hahn, Jin-Oh and Mahajan, Aman and Shroff, Sanjeev G and Mukkamala, Ramakrishna},
  title = {Mathematical Modeling of Oscillometric Blood Pressure Measurement: A Complete, Reduced Oscillogram Model},
  journal = {IEEE Transactions on Biomedical Engineering},
  year = {2023},
  volume = {70},
  number = {2},
  pages = {715--722},
  doi = {10.1109/tbme.2022.3201433}
}
Kostenlos starten →