EUVIMEDEUVIMED entdecken
Crossref

Low-Power OOK Transceiver With Auto-Feedback Calibrator in Receiver and Harmonic Mitigation Technique in Transmitter for Implantable Devices

Shuenn-Yuh Lee, Che-Tien Shen, Yu-Hsiang Wang

IEEE Transactions on Biomedical Circuits and Systems · 2026

DOI: 10.1109/tbcas.2026.3695084 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Biomedical Circuits and Systems, 2026. Verfasst von Shuenn-Yuh Lee und 2 weiteren Autor:innen. Hauptthemen laut MEDLINE: Signal Processing, Computer-Assisted, Wireless Technology, Prostheses and Implants. Die Arbeit nennt 26 Literaturangaben. Gefördert von: Taiwan Semiconductor Research Institute and the National Science and Technology Council, (NSTC), Taiwan, R.O.C., Yushan Fellow Program, Ministry of Education (MOE), Taiwan, Higher Education Sprout Project, MOE, Taiwan, to the Headquarters of University Advancement at National Cheng Kung University, Taiwan.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This article presents the design and implementation of a highly integrated, low-power on-off keying (OOK) transceiver for energy-efficient wireless communication in the 2.4 GHz Industrial Scientific Medical band. The receiver integrates a novel single-to-differential envelope detector paired with an auto-feedback calibrator (AFC), thereby enhancing sensitivity while minimizing power consumption and chip area. By eliminating the need for a large-area balun and leveraging the AFC, the receiver optimizes signal detection performance. The transmitter incorporates a current-reused self-mixing voltage-controlled oscillator to reduce energy consumption, along with a quadruple-transconductance power amplifier to suppress second-order harmonic distortion. The entire transceiver is fabricated using TSMC 0.18 µm CMOS technology. For short-range operation at a carrier frequency of 2.45 GHz, the receiver achieves a sensitivity of -38.8 dBm at a 2 Mbps data rate. Meanwhile, the transmitter supplies 16.3 dBm output power and supports data rates of up to 30 Mbps. Operating from a 1.2 V supply, the receiver and transmitter consume only 8.7 µW and 0.856 mW, respectively. Overall, these results yield an energy-per-bit of 4.35 pJ/bit for the receiver and a figure of merit of 10.47 for the transmitter, highlighting the transceiver's suitability for low-power, high-efficiency implantable or wearable applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Signal Processing, Computer-AssistedWireless TechnologyProstheses and ImplantsEquipment DesignCalibrationHumans

Förderung

  • Taiwan Semiconductor Research Institute and the National Science and Technology Council, (NSTC), Taiwan, R.O.C.
  • Yushan Fellow Program, Ministry of Education (MOE), Taiwan
  • Higher Education Sprout Project, MOE, Taiwan, to the Headquarters of University Advancement at National Cheng Kung University, Taiwan

Zitieren

APA

Lee, S. Y., Shen, C. T., & Wang, Y. H. (2026). Low-Power OOK Transceiver With Auto-Feedback Calibrator in Receiver and Harmonic Mitigation Technique in Transmitter for Implantable Devices. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2026.3695084

Vancouver

Lee SY, Shen CT, Wang YH. Low-Power OOK Transceiver With Auto-Feedback Calibrator in Receiver and Harmonic Mitigation Technique in Transmitter for Implantable Devices. IEEE Transactions on Biomedical Circuits and Systems. 2026. doi:10.1109/tbcas.2026.3695084

BibTeX
@article{Lee2026,
  author = {Lee, Shuenn-Yuh and Shen, Che-Tien and Wang, Yu-Hsiang},
  title = {Low-Power OOK Transceiver With Auto-Feedback Calibrator in Receiver and Harmonic Mitigation Technique in Transmitter for Implantable Devices},
  journal = {IEEE Transactions on Biomedical Circuits and Systems},
  year = {2026},
  doi = {10.1109/tbcas.2026.3695084}
}
Kostenlos starten →