EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Development and Bench-to-Human Feasibility Evaluation of a Wireless Pinch-and-Grip Dynamometer

Ali Pourhossein iD, Mohamed Mehdi Ouerghi, Elisabeth Kuborn, Doguhan Tasdemir iD, Viktor Warwas, Charmayne Mary Lee Hughes iD

IEEE Journal of Translational Engineering in Health and Medicine · 2026 · 14 · 330-338

DOI: 10.1109/jtehm.2026.3720716 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Journal of Translational Engineering in Health and Medicine, 2026. Verfasst von Ali Pourhossein und 5 weiteren Autor:innen. Beteiligte Einrichtung: Faculty V-Mechanical Engineering and Transport Systems, Institute of Psychology and ErgonomicsTechnische Universität Berlin Berlin 10623 Germany. Hauptthemen laut MEDLINE: Hand Strength, Muscle Strength Dynamometer, Wireless Technology, Pinch Strength. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

This study presents MeRKeL, a portable wireless system designed for quantitative, reference-calibrated assessment of pinch and grip strength, and evaluates its technical validity and human feasibility under standardized laboratory conditions.

Methods

The system consists of two compact and functionally aligned modules (pinch and grip dynamometer) sharing a unified electronic architecture and data acquisition pipeline. Both employ task-specific mechanical designs tailored to the distinct loading characteristics of pinch and grip actions. Reference-based calibration and bench validation were performed across the full operating ranges and across multiple units. Accuracy, agreement, and within-session repeatability were evaluated using root mean squared error (RMSE), Bland–Altman analysis, and intraclass correlation coefficient (ICC). Feasibility testing in 196 healthy adults examined associations between maximal strength and demographic, behavioral, and health-related variables.

Results

Bench validation showed high agreement with the calibrated reference instrument (pinch: RMSE = 0.95 N, bias $= -0.56$ N; grip: RMSE = 1.86 N, bias $= -1.10$ N), and within-session repeatability was excellent (MDC95 pinch = 0.86 N; grip = 1.43 N). Experimental testing reproduced expected associations with key demographic and behavioral factors.

Conclusion

The MeRKeL system enables accurate and repeatable, reference-calibrated wireless measurement of pinch and grip strength, establishing a robust technical foundation for subsequent clinical evaluation and future home-based neuromuscular monitoring studies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hand StrengthMuscle Strength DynamometerWireless TechnologyPinch StrengthHumansFemaleFeasibility StudiesAdultMaleEquipment DesignReproducibility of ResultsMiddle AgedYoung AdultCalibration

Stichwörter der Autor:innen

Dynamometergrip strengthmetrologypinch strengthrepeatable wireless pinch and grip force measurements under standardized condit…supporting future clinical-comparator studies and home-based monitoring validat…translational engineering. Clinical and Translational Impact: The MeRKeL system…wireless sensor system

Autor:innen und Institutionen

  • Faculty V-Mechanical Engineering and Transport Systems, Institute of Psychology and ErgonomicsTechnische Universität Berlin Berlin 10623 Germany.

ORCID-Profile: Ali Pourhossein, Doguhan Tasdemir, Charmayne Mary Lee Hughes

Zitieren

APA

Pourhossein, A., Ouerghi, M. M., Kuborn, E., Tasdemir, D., Warwas, V., & Hughes, C. M. L. (2026). Development and Bench-to-Human Feasibility Evaluation of a Wireless Pinch-and-Grip Dynamometer. IEEE Journal of Translational Engineering in Health and Medicine, 14, 330-338. https://doi.org/10.1109/jtehm.2026.3720716

Vancouver

Pourhossein A, Ouerghi MM, Kuborn E, Tasdemir D, Warwas V, Hughes CML. Development and Bench-to-Human Feasibility Evaluation of a Wireless Pinch-and-Grip Dynamometer. IEEE Journal of Translational Engineering in Health and Medicine. 2026;14:330-338. doi:10.1109/jtehm.2026.3720716

BibTeX
@article{Pourhossein2026,
  author = {Pourhossein, Ali and Ouerghi, Mohamed Mehdi and Kuborn, Elisabeth and Tasdemir, Doguhan and Warwas, Viktor and Hughes, Charmayne Mary Lee},
  title = {Development and Bench-to-Human Feasibility Evaluation of a Wireless Pinch-and-Grip Dynamometer},
  journal = {IEEE Journal of Translational Engineering in Health and Medicine},
  year = {2026},
  volume = {14},
  pages = {330--338},
  doi = {10.1109/jtehm.2026.3720716}
}
Kostenlos starten →