EUVIMEDEUVIMED entdecken
Crossref

A 4.5 $\mu$W Miniaturized 3-Channel Wireless Intra-Cardiac Acquisition System

Yasser Rezaeiyan, Yarallah Koolivand, Milad Zamani, Omid Shoaei, Meysam Akbari, Farshad Moradi, Kea-Tiong Tang

IEEE Transactions on Biomedical Circuits and Systems · 2023

DOI: 10.1109/tbcas.2023.3294560 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Biomedical Circuits and Systems, 2023. Verfasst von Yasser Rezaeiyan und 6 weiteren Autor:innen. Hauptthemen laut MEDLINE: Electrocardiography, Telemetry. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 39 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This article presents a chip designed for wireless intra-cardiac monitoring systems. The design consists of a three-channel analog front-end, a pulse-width modulator featuring output-frequency offset and temperature calibration, and inductive data telemetry. By employing a resistance boosting technique in the instrumentation amplifier feedback, the pseudo-resistor exhibits lower non-linearity, leading to a total harmonic distortion of below 0.1%. Furthermore, the boosting technique enhances the feedback resistance, leading to a reduction in the size of the feedback capacitor and, consequently, the overall size. To make the modulator's output frequency resilient to temperature and process changes, coarse and fine-tuning algorithms are used. The front-end channel is capable of extracting the intra-cardiac signal with an effective number of bits of 8.9, while exhibiting an input-referred noise of less than 2.7 μVrms, and consuming 200 nW per channel. The front-end output is encoded by an ASK-PWM modulator, which drives an on-chip transmitter at 13.56 MHz. The proposed System-on-Chip (SoC) is fabricated in a 0.18 μm standard CMOS technology and consumes 4.5 μW while occupying 1.125 mm2.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectrocardiographyTelemetryMonitoring, PhysiologicAmplifiers, ElectronicAlgorithmsWireless TechnologySignal Processing, Computer-AssistedEquipment Design

Zitieren

APA

Rezaeiyan, Y., Koolivand, Y., Zamani, M., Shoaei, O., Akbari, M., Moradi, F., & Tang, K. T. (2023). A 4.5 $\mu$W Miniaturized 3-Channel Wireless Intra-Cardiac Acquisition System. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2023.3294560

Vancouver

Rezaeiyan Y, Koolivand Y, Zamani M, Shoaei O, Akbari M, Moradi F, et al. A 4.5 $\mu$W Miniaturized 3-Channel Wireless Intra-Cardiac Acquisition System. IEEE Transactions on Biomedical Circuits and Systems. 2023. doi:10.1109/tbcas.2023.3294560

BibTeX
@article{Rezaeiyan2023,
  author = {Rezaeiyan, Yasser and Koolivand, Yarallah and Zamani, Milad and Shoaei, Omid and Akbari, Meysam and Moradi, Farshad and Tang, Kea-Tiong},
  title = {A 4.5 $\mu$W Miniaturized 3-Channel Wireless Intra-Cardiac Acquisition System},
  journal = {IEEE Transactions on Biomedical Circuits and Systems},
  year = {2023},
  doi = {10.1109/tbcas.2023.3294560}
}
Kostenlos starten →