EUVIMEDEUVIMED entdecken
Open Access

A Study on Ultrasonic Wireless Power Transfer With Phased Array for Biomedical Implants

Zeinab Kashani, Mehdi Kiani

IEEE Transactions on Biomedical Circuits and Systems · 2023

DOI: 10.1109/tbcas.2023.3282197 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Biomedical Circuits and Systems, 2023. Verfasst von Zeinab Kashani und 1 weiteren Autor:innen. Hauptthemen laut MEDLINE: Ultrasonics, Wireless Technology. Die Arbeit wurde bisher 28-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NEI NIH HHS, National Institutes of Health, National Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This article presents the design, fabrication, and sensitivity analysis of an ultrasound (US) wireless power transfer (WPT) link using an external phased array. Optimal beam focusing and steering is needed for efficient, safe, and reliable US WPT to biomedical implants with millimeter (mm) dimensions. Therefore, the main contributions of this work include the investigation of the 1) performance of the US WPT link using different mm-sized US receivers, 2) effect of different types of errors in the delay profile of the beamforming system on the delivered power, and 3) implant's localization. In measurements, the fabricated 0.94 MHz, 32-element array (39.48 × 9.6 × 2 mm3) driven by 25 V pulses with beam focusing and steering capability up to 50 mm depth and ±60o angle could deliver power to different mm-sized US receivers within the FDA safety limit of 720 mW/cm2. Specifically, several US transducers with a 1 mm dimension (sphere, cubic, disc shape) and 2 mm dimension (disc shape) received 0.095 mW, 0.25 mW, 0.22 mW, and 0.53 mW, respectively, at a 30 mm depth (0o steering angle). Among these transducers, the sphere shape transducer featured less sensitivity to misalignments. A random error in the phased array delays had a more drastic effect on delivered power reduction. For implant's localization, the measurement results demonstrated comparable power delivery by measuring pulse delays of only 5 elements (out of 32 elements) using 4 different interpolation methods.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

UltrasonicsWireless TechnologyEquipment DesignUltrasonographyProstheses and ImplantsTransducers

Förderung

  • NEI NIH HHS
  • National Institutes of Health
  • National Science Foundation

Zitieren

APA

Kashani, Z., & Kiani, M. (2023). A Study on Ultrasonic Wireless Power Transfer With Phased Array for Biomedical Implants. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2023.3282197

Vancouver

Kashani Z, Kiani M. A Study on Ultrasonic Wireless Power Transfer With Phased Array for Biomedical Implants. IEEE Transactions on Biomedical Circuits and Systems. 2023. doi:10.1109/tbcas.2023.3282197

BibTeX
@article{Kashani2023,
  author = {Kashani, Zeinab and Kiani, Mehdi},
  title = {A Study on Ultrasonic Wireless Power Transfer With Phased Array for Biomedical Implants},
  journal = {IEEE Transactions on Biomedical Circuits and Systems},
  year = {2023},
  doi = {10.1109/tbcas.2023.3282197}
}
Kostenlos starten →