EUVIMEDEUVIMED entdecken
Crossref

Cage-Embedded Crown-Type Dual Coil Wireless Power Transfer Based Microwave Brain Stimulation System for Untethered and Moving Mice

Jinhyun Kim, Sanggeon Park, Seongwoog Oh, Yeowool Huh, Jeiwon Cho, Jungsuek Oh

IEEE Transactions on Biomedical Circuits and Systems · 2023

DOI: 10.1109/tbcas.2023.3255248 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Biomedical Circuits and Systems, 2023. Verfasst von Jinhyun Kim und 5 weiteren Autor:innen. Hauptthemen laut MEDLINE: Microwaves, Wireless Technology. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 54 Literaturangaben. Gefördert von: National Research Foundation of Korea, Ministry of Science and ICT, South Korea, Creative-Pioneering Researchers Program through Seoul National University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study proposes a novel brain-stimulated mouse experiment system which is insensitive to the variations in the position and orientation of a mouse. This is achieved by the proposed novel crown-type dual coil system for magnetically coupled resonant wireless power transfer (MCR-WPT). In the detailed system architecture, the transmitter coil consists of a crown-type outer coil and a solenoid-type inner coil. The crown-type coil was constructed by repeating the rising and falling at an angle of 15 ° for each side which creates the H-field diverse direction. The solenoid-type inner coil creates a magnetic field distributed uniformly along the location. Therefore, despite using two coils for the Tx system, the system generates the H-field insensitive to the variations in the position and angle of the receiver system. The receiver is comprised of the receiving coil, rectifier, divider, LED indicator, and the MMIC that generates the microwave signal for stimulating the brain of the mouse. The system resonating at 2.84 MHz was simplified to easy fabrication by constructing 2 transmitter coils and 1 receiver coil. A peak PTE of 19.6% and a PDL of 1.93 W were achieved, and the system also achieved an operation time ratio of 89.55% in vivo experiments. As a result, it is confirmed that experiments could proceed for approximately 7 times longer through the proposed system compared to the conventional dual coil system.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MicrowavesWireless TechnologyMiceAnimalsElectric Power Supplies

Förderung

  • National Research Foundation of Korea
  • Ministry of Science and ICT, South Korea
  • Creative-Pioneering Researchers Program through Seoul National University

Zitieren

APA

Kim, J., Park, S., Oh, S., Huh, Y., Cho, J., & Oh, J. (2023). Cage-Embedded Crown-Type Dual Coil Wireless Power Transfer Based Microwave Brain Stimulation System for Untethered and Moving Mice. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2023.3255248

Vancouver

Kim J, Park S, Oh S, Huh Y, Cho J, Oh J. Cage-Embedded Crown-Type Dual Coil Wireless Power Transfer Based Microwave Brain Stimulation System for Untethered and Moving Mice. IEEE Transactions on Biomedical Circuits and Systems. 2023. doi:10.1109/tbcas.2023.3255248

BibTeX
@article{Kim2023,
  author = {Kim, Jinhyun and Park, Sanggeon and Oh, Seongwoog and Huh, Yeowool and Cho, Jeiwon and Oh, Jungsuek},
  title = {Cage-Embedded Crown-Type Dual Coil Wireless Power Transfer Based Microwave Brain Stimulation System for Untethered and Moving Mice},
  journal = {IEEE Transactions on Biomedical Circuits and Systems},
  year = {2023},
  doi = {10.1109/tbcas.2023.3255248}
}
Kostenlos starten →