Mechanical Response Analysis of HTS Transformer Windings Under External Short-Circuit Impacts

Chengxiang Liu, Caiyong Ye, Zhuoyan Zhong, Bing Xue, Chenguang Yan, Shuhao Peng, Youping Li, Junqing Wang, Bo Ren, Xueliang Wang, Xinyan Xie

IEEE Transactions on Applied Superconductivity · 2026-08 · 36 (5) · 4607709-4607709

DOI: 10.1109/tasc.2026.3702999 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Applied Superconductivity, 2026-08. Verfasst von Chengxiang Liu und 10 weiteren Autor:innen. Die Arbeit nennt 38 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

High-temperature superconducting (HTS) transformers have great potential in power system applications, such as smaller size and weight, fault and short-circuit current limiting, and high power density. Nevertheless, the mechanical behavior of their windings to external short-circuit electromagnetic forces needs additional in-depth research. This study investigates the mechanical response of HTS transformer windings subjected to external short-circuit impacts. A field-circuit coupled simulation is developed to calculate short-circuit current and the corresponding leakage magnetic field distribution, from which the electromagnetic forces acting on the windings are derived. The mechanical properties of the REBCO superconducting tape are homogenized using the representative volume element method, and a local mechanical finite element (FE) model is constructed to simulate the mechanical response under these force loads. A 500 kVA HTS transformer serves as the case study, enabling analysis of the short-circuit current distribution, electromagnetic forces, and the resulting stress, strain, and deformation. The results show that, under the investigated fault condition, the peak short-circuit current reaches 7.67 times the rated peak current. This current is then used to characterize the electromagnetic loading for mechanical analysis. The end pancakes experience high axial and radial electromagnetic forces, causing significant stress concentrations, whereas the middle pancakes are mainly subjected to radial forces, leading to a comparatively lower mechanical response. These findings elucidate the mechanical behavior of the windings under short-circuit conditions, thereby providing a basis for structural optimization and mechanical reliability assessment.

Zitieren

APA

Liu, C., Ye, C., Zhong, Z., Xue, B., Yan, C., Peng, S., Li, Y., Wang, J., Ren, B., Wang, X., & Xie, X. (2026). Mechanical Response Analysis of HTS Transformer Windings Under External Short-Circuit Impacts. IEEE Transactions on Applied Superconductivity, 36(5), 4607709-4607709. https://doi.org/10.1109/tasc.2026.3702999

Vancouver

Liu C, Ye C, Zhong Z, Xue B, Yan C, Peng S, et al. Mechanical Response Analysis of HTS Transformer Windings Under External Short-Circuit Impacts. IEEE Transactions on Applied Superconductivity. 2026;36(5):4607709-4607709. doi:10.1109/tasc.2026.3702999

BibTeX
@article{Liu2026,
  author = {Liu, Chengxiang and Ye, Caiyong and Zhong, Zhuoyan and Xue, Bing and Yan, Chenguang and Peng, Shuhao and Li, Youping and Wang, Junqing and Ren, Bo and Wang, Xueliang and Xie, Xinyan},
  title = {Mechanical Response Analysis of HTS Transformer Windings Under External Short-Circuit Impacts},
  journal = {IEEE Transactions on Applied Superconductivity},
  year = {2026},
  volume = {36},
  number = {5},
  pages = {4607709--4607709},
  doi = {10.1109/tasc.2026.3702999}
}
Kostenlos starten →