Spatial Coherence Adaptive Clutter Filtering in Color Flow Imaging—Part II: Phantom and In Vivo Experiments
IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control · 2022
DOI: 10.1109/ojuffc.2022.3184909 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control, 2022. Verfasst von Will Long und 4 weiteren Autor:innen. Beteiligte Einrichtung: Philips, Cambridge, MA 02141 USA. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIBIB NIH HHS, National Institute of Biomedical Imaging and Bioengineering.
Abstract (Originalsprache)
Conventional color flow processing is associated with a high degree of operator dependence, often requiring the careful tuning of clutter filters and priority encoding to optimize the display and accuracy of color flow images. In a companion paper, we introduced a novel framework to adapt color flow processing based on local measurements of backscatter spatial coherence. Through simulation studies, the adaptive selection of clutter filters using coherence image quality characterization was demonstrated as a means to dynamically suppress weakly-coherent clutter while preserving coherent flow signal in order to reduce velocity estimation bias. In this study, we extend previous work to evaluate the application of coherence-adaptive clutter filtering (CACF) on experimental data acquired from both phantom and in vivo liver and fetal vessels. In phantom experiments with clutter-generating tissue, CACF was shown to increase the dynamic range of velocity estimates and decrease bias and artifact from flash and thermal noise relative to conventional color flow processing. Under in vivo conditions, such properties allowed for the direct visualization of vessels that would have otherwise required fine-tuning of filter cutoff and priority thresholds with conventional processing. These advantages are presented alongside various failure modes identified in CACF as well as discussions of solutions to mitigate such limitations.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Philips, Cambridge, MA 02141 USA.
- Department of Biomedical Engineering, Duke University, Durham, NC 27708 USA.
- Department of Radiology, Duke University Medical Center, Durham, NC 27710 USA.
ORCID-Profile: David Bradway, Rifat Ahmed
Förderung
- NIBIB NIH HHS
- National Institute of Biomedical Imaging and Bioengineering
Zitieren
APA
Long, W., Bradway, D., Ahmed, R., Long, J., & Trahey, G. E. (2022). Spatial Coherence Adaptive Clutter Filtering in Color Flow Imaging—Part II: Phantom and In Vivo Experiments. IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control. https://doi.org/10.1109/ojuffc.2022.3184909
Vancouver
Long W, Bradway D, Ahmed R, Long J, Trahey GE. Spatial Coherence Adaptive Clutter Filtering in Color Flow Imaging—Part II: Phantom and In Vivo Experiments. IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control. 2022. doi:10.1109/ojuffc.2022.3184909
BibTeX
@article{Long2022,
author = {Long, Will and Bradway, David and Ahmed, Rifat and Long, James and Trahey, Gregg E},
title = {Spatial Coherence Adaptive Clutter Filtering in Color Flow Imaging—Part II: Phantom and In Vivo Experiments},
journal = {IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control},
year = {2022},
doi = {10.1109/ojuffc.2022.3184909}
}
EUVIMED