Ultrafast Online Clutter Filtering for Ultrasound Microvascular Imaging
IEEE Transactions on Medical Imaging · 2025-06 · 44 (6) · 2477-2491
DOI: 10.1109/tmi.2025.3535550 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Medical Imaging, 2025-06. Verfasst von Yinran Chen und 4 weiteren Autor:innen. Hauptthemen laut MEDLINE: Microvessels, Image Processing, Computer-Assisted, Signal Processing, Computer-Assisted. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Xiamen, China, Fujian Provincial Natural Science Foundation of China.
Abstract (Originalsprache)
Spatiotemporal clutter filtering via robust principal component analysis (rPCA) has been widely used in ultrasound microvascular imaging. However, the performance of the rPCA clutter filtering highly relies on low-rank modeling for tissue signals and sparse modeling for blood flow signals. Moreover, current rPCA clutter filters are typically based on static processing and have to access a batch of beamformed frames for optimization. This prevents these filters from ultrafast realization. This paper adopts the iteratively reweighted least squares (IRLS) rPCA framework to model tissue and blood flow signals for improved clutter filtering. More importantly, the static IRLS-rPCA filter is upgraded to a spatiotemporal-constrained online method to instantaneously extract blood flow signals from the ongoing beamformed frame. Simulations and in-vivo experiments on a contrast-enhanced rat kidney and a contrast-free human liver demonstrated that the IRLS-rPCA clutter filter achieves higher sensitivity, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) than other rPCA methods. Particularly, the static IRLS-rPCA clutter filter obtains more than 2 dB improvements in CNR over the compared methods in the human liver dataset. The proposed online clutter filter achieves comparable image quality to the static version and processing time of $0.028~\pm ~0.004$ seconds per frame. The corresponding acceleration factor of the online clutter filter over all the tested methods is more than 20.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Förderung
- National Natural Science Foundation of China
- Natural Science Foundation of Xiamen, China
- Fujian Provincial Natural Science Foundation of China
- Fundamental Research Funds for the Central Universities
Zitieren
APA
Chen, Y., Fang, B., Li, H., Huang, L., & Luo, J. (2025). Ultrafast Online Clutter Filtering for Ultrasound Microvascular Imaging. IEEE Transactions on Medical Imaging, 44(6), 2477-2491. https://doi.org/10.1109/tmi.2025.3535550
Vancouver
Chen Y, Fang B, Li H, Huang L, Luo J. Ultrafast Online Clutter Filtering for Ultrasound Microvascular Imaging. IEEE Transactions on Medical Imaging. 2025;44(6):2477-2491. doi:10.1109/tmi.2025.3535550
BibTeX
@article{Chen2025,
author = {Chen, Yinran and Fang, Baohui and Li, Huaying and Huang, Lijie and Luo, Jianwen},
title = {Ultrafast Online Clutter Filtering for Ultrasound Microvascular Imaging},
journal = {IEEE Transactions on Medical Imaging},
year = {2025},
volume = {44},
number = {6},
pages = {2477--2491},
doi = {10.1109/tmi.2025.3535550}
}
EUVIMED