EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Lead-Aware Multi-Resolution Transformer With Domain Adaptation for Beat-Level ECG Arrhythmia Classification

Masuduzzaman Niloy, Md Tanzimul Islam, Md Shafiq Ullah, Jobayar Alom, Mumtahina Ahmed, M. F. Mridha, Md. Jakir Hossen

IEEE Open Journal of the Computer Society · 2025 · 6 · 1946-1957

DOI: 10.1109/ojcs.2025.3637851 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Open Journal of the Computer Society, 2025. Verfasst von Masuduzzaman Niloy und 6 weiteren Autor:innen. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate and generalizable ECG classification remains a critical challenge in automated cardiac diagnostics, particularly when dealing with multi-lead signals from heterogeneous sources. In this paper, we propose MuRe-LAT, a Multi-Resolution Lead-Aware Transformer architecture with domain-adaptive normalization designed for robust arrhythmia detection. The model integrates a convolutional stem for local feature extraction, a lead attention module to adaptively weigh channel contributions, dual-scale transformer encoders for capturing both short-term and long-term dependencies, and a domain-specific batch normalization mechanism to mitigate dataset shift. To enhance generalization, MuRe-LAT is pretrained using a masked signal modeling objective. We evaluate the model on two benchmark datasets MIT-BIH Arrhythmia and PTB-XL spanning both ambulatory and clinical ECG recordings. On MIT-BIH, MuRe-LAT achieves an accuracy of 94.0%, a macro-F1 of 88.4, an AUROC of 96.2, and a PR-AUC of 91.6; on PTB-XL, it reaches 88.7% accuracy, 78.1 macro-F1, and 90.5 AUROC. The model also demonstrates strong cross-domain generalization, achieving up to 91.7% accuracy when transferred from PTB-XL to MIT-BIH without retraining. Compared to strong baselines including ResNet-1D, BiLSTM, ECG-BERT, and CardioFormer, MuRe-LAT outperforms or closely matches state-of-the-art results in over 90% of evaluation settings. With only 12.3M parameters and an inference time of 8.4 ms per 10-second ECG window, MuRe-LAT offers a compelling balance between accuracy and efficiency, making it suitable for deployment in real-time clinical and wearable applications.

Zitieren

APA

Niloy, M., Islam, M. T., Ullah, M. S., Alom, J., Ahmed, M., Mridha, M. F., & Hossen, M. J. (2025). Lead-Aware Multi-Resolution Transformer With Domain Adaptation for Beat-Level ECG Arrhythmia Classification. IEEE Open Journal of the Computer Society, 6, 1946-1957. https://doi.org/10.1109/ojcs.2025.3637851

Vancouver

Niloy M, Islam MT, Ullah MS, Alom J, Ahmed M, Mridha MF, et al. Lead-Aware Multi-Resolution Transformer With Domain Adaptation for Beat-Level ECG Arrhythmia Classification. IEEE Open Journal of the Computer Society. 2025;6:1946-1957. doi:10.1109/ojcs.2025.3637851

BibTeX
@article{Niloy2025,
  author = {Niloy, Masuduzzaman and Islam, Md Tanzimul and Ullah, Md Shafiq and Alom, Jobayar and Ahmed, Mumtahina and Mridha, M. F. and Hossen, Md. Jakir},
  title = {Lead-Aware Multi-Resolution Transformer With Domain Adaptation for Beat-Level ECG Arrhythmia Classification},
  journal = {IEEE Open Journal of the Computer Society},
  year = {2025},
  volume = {6},
  pages = {1946--1957},
  doi = {10.1109/ojcs.2025.3637851}
}
Kostenlos starten →