A CubeSat-Compatible Optothermal Sensing Platform for Biofilm Fluorescence Monitoring
IEEE Sensors Journal · 2026-11 · 26 (21) · 33434-33445
DOI: 10.1109/jsen.2026.3734110 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Sensors Journal, 2026-11. Verfasst von Giulia Petrucci und 12 weiteren Autor:innen. Die Arbeit nennt 64 Literaturangaben. Gefördert von: Italian Space Agency Within the Framework of the ALCOR Program, Tender Identification Code, Unique Project Code.
Abstract (Originalsprache)
This article presents a compact optothermal sensing platform (OSP) developed as the core transducer of the biofilm onboard radiation exposure assessment lab in space (BOREALIS) CubeSat payload. The platform operates in reflection mode beneath a movable PMMA microfluidic chip and integrates patterned optical filtering, thin-film photodetection, local thermal actuation, temperature sensing, and optical shielding, while being interfaced with custom front-end electronics and payload-level data acquisition. The OSP includes a patterned SiO2/TiO2 interference filter that rejects the 470–490 nm excitation band while preserving transmission above 500 nm. The platform integrates two optical sensing sites, each based on a lithographically defined excitation aperture in the filter. Each aperture is surrounded by 16 hydrogenated amorphous silicon (a-Si:H) p-i-n photodiodes. The same device incorporates a-Si:H temperature sensors and chromium/aluminum/chromium (Cr/Al/Cr) lateral thin-film heaters. Optical characterization showed 90%–95% transmission through the excitation apertures, low dark-current densities of the photosensors, and spectral selectivity compatible with green fluorescent-protein (GFP) fluorescence detection. Thermal characterization demonstrated localized heating of the active region, agreement between simulations and thermography, and a temperature-sensor sensitivity of approximately–3.75 mV °C ${}^{-{1}}$ . Integrated breadboard tests using a 470-nm LED, custom low-noise readout electronics, syringe-pump-driven microfluidics, fluorescein solutions, and preliminary measurements on a GFP-expressing Escherichia coli biofilm sample validated the OSP as the sensing core of a CubeSat-compatible fluorescence platform.
Förderung
- Italian Space Agency Within the Framework of the ALCOR Program
- Tender Identification Code
- Unique Project Code
- BOREALIS Project
Zitieren
APA
Petrucci, G., Lovecchio, N., Nardi, L., Abbasrezaee, P., Emani, V. S. S. S., Sriramoju, S., Omrani, V., Mazidi, Z., Granello, P., Cappelli, F., Caputo, D., Mirasoli, M., & Nascetti, A. (2026). A CubeSat-Compatible Optothermal Sensing Platform for Biofilm Fluorescence Monitoring. IEEE Sensors Journal, 26(21), 33434-33445. https://doi.org/10.1109/jsen.2026.3734110
Vancouver
Petrucci G, Lovecchio N, Nardi L, Abbasrezaee P, Emani VSSS, Sriramoju S, et al. A CubeSat-Compatible Optothermal Sensing Platform for Biofilm Fluorescence Monitoring. IEEE Sensors Journal. 2026;26(21):33434-33445. doi:10.1109/jsen.2026.3734110
BibTeX
@article{Petrucci2026,
author = {Petrucci, Giulia and Lovecchio, Nicola and Nardi, Lorenzo and Abbasrezaee, Parsa and Emani, Venkata Sai Siva Sankaram and Sriramoju, Sahithi and Omrani, Vahid and Mazidi, Zahra and Granello, Pierpaolo and Cappelli, Fabio and Caputo, Domenico and Mirasoli, Mara and Nascetti, Augusto},
title = {A CubeSat-Compatible Optothermal Sensing Platform for Biofilm Fluorescence Monitoring},
journal = {IEEE Sensors Journal},
year = {2026},
volume = {26},
number = {21},
pages = {33434--33445},
doi = {10.1109/jsen.2026.3734110}
}
EUVIMED