Evaluation of Low-Gain Avalanche Detectors (LGADs) Coupled to the Timepix3 ASIC Using a Micro-Focused X-Ray Beam
IEEE Sensors Journal · 2026-11 · 26 (21) · 32455-32463
DOI: 10.1109/jsen.2026.3733349 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Sensors Journal, 2026-11. Verfasst von Dzmitry Maneuski und 7 weiteren Autor:innen. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science and Technology Facilities Council, European Union’s Horizon Europe Research and Innovation Program, Spanish Ministry of Science, Innovation, and Universities.
Abstract (Originalsprache)
In this work, the properties of 200- $\mu $ m thick highly pixelated low-gain avalanche detector (LGAD) sensors bonded to the Timepix3 readout ASIC were characterized with a monochromatic micro-focused X-ray beam for the first time. Recent advances in the control of the LGAD fabrication process by Micron Semiconductor Ltd. have allowed the manufacture of highly segmented devices where each pixel has an internal gain. Devices with 55- $\mu $ m pixels with 5- $\mu $ m junction termination extension (JTE), 110- $\mu $ m pixels with 10- $\mu $ m JTE, and 110- $\mu $ m pixels with 20- $\mu $ m JTE were bump-bonded to a Timepix3 readout ASIC. These were characterized with a monochromatic, micro-focused 15-keV X-ray beam at a synchrotron. The performance of the LGAD devices is benchmarked against a standard 55- $\mu $ m pixel planar device. The evidence of $\times {3}.{5}$ gain is demonstrated on the $110\times 10$ - $\mu $ m JTE pixel device, while the 55- $\mu $ m assembly showed no gain, which was consistent with simulations. This article provides a comprehensive analysis of the spectrum, pixel profile, and 2-D mapping scans.
Förderung
- Science and Technology Facilities Council
- European Union’s Horizon Europe Research and Innovation Program
- Spanish Ministry of Science, Innovation, and Universities
- HLP Scholarship from the Public Service Department, Government of Malaysia
Zitieren
APA
Maneuski, D., Moffat, N., Alozy, J., Eklund, L., Lombigit, L., Tartoni, N., Bullough, M., & Bates, R. (2026). Evaluation of Low-Gain Avalanche Detectors (LGADs) Coupled to the Timepix3 ASIC Using a Micro-Focused X-Ray Beam. IEEE Sensors Journal, 26(21), 32455-32463. https://doi.org/10.1109/jsen.2026.3733349
Vancouver
Maneuski D, Moffat N, Alozy J, Eklund L, Lombigit L, Tartoni N, et al. Evaluation of Low-Gain Avalanche Detectors (LGADs) Coupled to the Timepix3 ASIC Using a Micro-Focused X-Ray Beam. IEEE Sensors Journal. 2026;26(21):32455-32463. doi:10.1109/jsen.2026.3733349
BibTeX
@article{Maneuski2026,
author = {Maneuski, Dzmitry and Moffat, Neil and Alozy, Jerome and Eklund, Lars and Lombigit, Lojius and Tartoni, Nicola and Bullough, Mark and Bates, Richard},
title = {Evaluation of Low-Gain Avalanche Detectors (LGADs) Coupled to the Timepix3 ASIC Using a Micro-Focused X-Ray Beam},
journal = {IEEE Sensors Journal},
year = {2026},
volume = {26},
number = {21},
pages = {32455--32463},
doi = {10.1109/jsen.2026.3733349}
}
EUVIMED