Frequency Doublet Resonance Detection Electronic Circuit for Piezoelectric Flexural Plate Wave MEMS Transducer
IEEE Sensors Journal · 2026-10 · 26 (19) · 28727-28734
DOI: 10.1109/jsen.2026.3725924 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Sensors Journal, 2026-10. Verfasst von Stefano Bertelli und 3 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Union—Next Generation EU.
Abstract (Originalsprache)
This article presents an innovative frequency doublet resonance detection (FDRD) technique and its implementation in a tailored electronic circuit coupled to a piezoelectric flexural plate wave (FPW) micro-electromechanical system (MEMS) transducer operated as a one-port resonator. The MEMS embeds a thin diaphragm made of highly doped silicon (HDS) and aluminum nitride (AlN) piezoelectric layers. Metal interdigital transducers (IDTs) excite and receive FPWs in the diaphragm at the first antisymmetric Lamb wave mode (A0). The diaphragm dimensions determine an acoustic cavity with a corresponding comb of resonances, of which one, denoted as $f_{\mathbf {r}}$ , is selected as the target resonance. The FDRD technique is based on the simultaneous excitation of the resonator port by a frequency doublet formed by two sinusoidal signals at frequencies $\textit {f}_{{1}}$ and $\textit {f}_{{2}}$ , separated by a fixed frequency gap $\Delta \textit {f}$ . The frequencies are swept in the range across $\textit {f}_{\text {r}}$ while measuring the port conductance difference at the two frequencies of the doublet. The resulting conductance difference nulls when the doublet center frequency equals $\textit {f}_{\text {r}}$ , thereby enabling resonance detection. By varying $\Delta \textit {f}$ , the frequency-to-voltage sensitivity of the proposed circuit around $\textit {f}_{\text {r}}$ can be tuned. The FDRD technique has been experimentally validated through a dedicated analog front-end circuit coupled to the MEMS transducer. The doublet frequencies were varied from 12.125 to 12.145 MHz with $\Delta \textit {f}$ ranging between 1 and 6 kHz. The measured circuit output led to the detection of the resonance at 12.1365 MHz, in agreement with reference measurements taken using an impedance analyzer. The maximum fractional error of the detected resonance is 8 ppm within the explored $\Delta \textit {f}$ range. The achieved results suggest that the proposed FDRD circuit can be suitably employed as a resonance detection front-end as the basic block for resonance locking and tracking in a closed-loop configuration.
Förderung
- European Union—Next Generation EU
Zitieren
APA
Bertelli, S., Nastro, A., Ferrari, M., & Ferrari, V. (2026). Frequency Doublet Resonance Detection Electronic Circuit for Piezoelectric Flexural Plate Wave MEMS Transducer. IEEE Sensors Journal, 26(19), 28727-28734. https://doi.org/10.1109/jsen.2026.3725924
Vancouver
Bertelli S, Nastro A, Ferrari M, Ferrari V. Frequency Doublet Resonance Detection Electronic Circuit for Piezoelectric Flexural Plate Wave MEMS Transducer. IEEE Sensors Journal. 2026;26(19):28727-28734. doi:10.1109/jsen.2026.3725924
BibTeX
@article{Bertelli2026,
author = {Bertelli, Stefano and Nastro, Alessandro and Ferrari, Marco and Ferrari, Vittorio},
title = {Frequency Doublet Resonance Detection Electronic Circuit for Piezoelectric Flexural Plate Wave MEMS Transducer},
journal = {IEEE Sensors Journal},
year = {2026},
volume = {26},
number = {19},
pages = {28727--28734},
doi = {10.1109/jsen.2026.3725924}
}
EUVIMED