EUVIMEDEUVIMED entdecken
Crossref

Physiology and Sampling-Frequency Adaptive Type-II Diabetes Detection Using PPG

Priya Sardar, Jayanta K. Chandra, Rajarshi Gupta, Arunansu Talukdar

IEEE Sensors Journal · 01.07.2026 · 26 (13) · 20191-20200

DOI: 10.1109/jsen.2026.3697135 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Sensors Journal, erschienen am 01.07.2026. Verfasst von Priya Sardar und 3 weiteren Autor:innen. Die Arbeit nennt 32 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Photoplethysmography (PPG) captures valuable information related to vascular and hemodynamic changes due to various cardiovascular and hemodynamic disorders. Recent research highlights PPG as a promising modality for noninvasive type-II diabetes detection. However, published models in this area are either computationally heavy or lack interpretability. Second, the trained model parameters being static, performance may degrade over time due to varied physiological conditions. This study proposes a new method of optimal frequency, along with ensemble empirical mode decomposition (EEMD) derived intrinsic mode function (IMF) selection based on a new parameter named discriminative index (DI). Using the publicly available photoplethysmography and blood pressure (PPG-BP) dataset, an accuracy of 91% for hypertensive subjects and 92% for prehypertensive and nonhypertensive subjects was obtained using random forest (RF) classifier. The algorithm also assesses the reliability of the prediction using a Kullback Leibler (KL) divergence and provides a decision whether retraining is required for the selection of the optimal feature for new test subjects. The end-to-end pipeline was also deployed in a resource-constrained hardware advanced RISC machine (ARM) v8 controller, with a low memory requirement of 2.73 MB and detection latency of 29.4 s to process 2.1 s PPG snippet. The proposed method can be useful for noninvasive diabetes sensor development toward improved diabetes management.

Zitieren

APA

Sardar, P., Chandra, J. K., Gupta, R., & Talukdar, A. (2026). Physiology and Sampling-Frequency Adaptive Type-II Diabetes Detection Using PPG. IEEE Sensors Journal, 26(13), 20191-20200. https://doi.org/10.1109/jsen.2026.3697135

Vancouver

Sardar P, Chandra JK, Gupta R, Talukdar A. Physiology and Sampling-Frequency Adaptive Type-II Diabetes Detection Using PPG. IEEE Sensors Journal. 2026;26(13):20191-20200. doi:10.1109/jsen.2026.3697135

BibTeX
@article{Sardar2026,
  author = {Sardar, Priya and Chandra, Jayanta K. and Gupta, Rajarshi and Talukdar, Arunansu},
  title = {Physiology and Sampling-Frequency Adaptive Type-II Diabetes Detection Using PPG},
  journal = {IEEE Sensors Journal},
  year = {2026},
  volume = {26},
  number = {13},
  pages = {20191--20200},
  doi = {10.1109/jsen.2026.3697135}
}
Kostenlos starten →