EUVIMEDEUVIMED entdecken
Crossref

Portable Pb²+ Potentiometric Sensor With Embedded Drift Correction

B. Suribabu Naick, S. Mallikarjunaiah, Srinivasulu A, K. Raj Kumar, S. M. K. Chaitanya, B. Maha Lakshmi, Kuruva Raju, Sreenivasulu Mamilla

IEEE Sensors Journal · 01.06.2026 · 26 (11) · 17125-17132

DOI: 10.1109/jsen.2026.3684199 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Sensors Journal, erschienen am 01.06.2026. Verfasst von B. Suribabu Naick und 7 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 23 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Reliable long-term monitoring of lead (Pb2+) contamination in water using ion-selective electrodes (ISEs) is fundamentally limited by baseline drift and signal instability during continuous operation. In this work, we present a drift-corrected potentiometric sensing system for Pb2+ detection that integrates a solid-contact Pb2+-selective electrode with an embedded digital signal-processing framework to enhance measurement stability over time. The proposed approach employs a real-time drift-correction algorithm implemented at the signal-conditioning stage, enabling effective suppression of open-circuit potential (OCP) drift without altering the membrane chemistry or electrode architecture. The Pb2+-selective electrode exhibits a near-Nernstian sensitivity of approximately 24 ± 0.2 mV/dec over a concentration range from 10−7 to 10−2 M. When combined with the proposed correction scheme, the system achieves a substantial reduction in baseline drift during continuous measurements while preserving accurate concentration readout. The sensing performance is validated using laboratory samples and real water samples, with the measured Pb2+ concentrations showing good agreement with inductively coupled plasma mass spectrometry (ICP-MS) analysis. Unlike prior Pb2+ sensing studies that primarily focus on material-level optimization, this work introduces a system-level driftcorrection strategy that improves the practical reliability of potentiometric ISEs for continuous environmental monitoring applications.

Zitieren

APA

Naick, B. S., Mallikarjunaiah, S., A, S., Kumar, K. R., Chaitanya, S. M. K., Lakshmi, B. M., Raju, K., & Mamilla, S. (2026). Portable Pb²+ Potentiometric Sensor With Embedded Drift Correction. IEEE Sensors Journal, 26(11), 17125-17132. https://doi.org/10.1109/jsen.2026.3684199

Vancouver

Naick BS, Mallikarjunaiah S, A S, Kumar KR, Chaitanya SMK, Lakshmi BM, et al. Portable Pb²+ Potentiometric Sensor With Embedded Drift Correction. IEEE Sensors Journal. 2026;26(11):17125-17132. doi:10.1109/jsen.2026.3684199

BibTeX
@article{Naick2026,
  author = {Naick, B. Suribabu and Mallikarjunaiah, S. and A, Srinivasulu and Kumar, K. Raj and Chaitanya, S. M. K. and Lakshmi, B. Maha and Raju, Kuruva and Mamilla, Sreenivasulu},
  title = {Portable Pb²+ Potentiometric Sensor With Embedded Drift Correction},
  journal = {IEEE Sensors Journal},
  year = {2026},
  volume = {26},
  number = {11},
  pages = {17125--17132},
  doi = {10.1109/jsen.2026.3684199}
}
Kostenlos starten →