EUVIMEDEUVIMED entdecken
Crossref

A 340-mg Fully Implantable Bidirectional Neuromodulation System Incorporating a Customized ASIC

Wenkai Jin, Liyang Wang, Yu Xia, Haochuan Wang, Guoqing Luo, Hui Hong, Yuhua Cheng, Mang-I Vai, Sio-Hang Pun, Nenggan Zheng

IEEE Sensors Journal · 15.02.2026 · 26 (4) · 5697-5709

DOI: 10.1109/jsen.2025.3648422 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Sensors Journal, erschienen am 15.02.2026. Verfasst von Wenkai Jin und 9 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 47 Literaturangaben. Gefördert von: “Pioneer” and “Leading Goose” Research and Development Program of Zhejiang, National Natural Science Foundation of China, National Key Research and Development Program of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Fully implantable brain-computer interfaces (BCIs) effectively mitigate the risk of infection while achieving high signal-to-noise ratio (SNR) neural signal recording, providing a reliable and efficient approach for decoding complex neural signals. However, challenges remain in miniaturization, efficient wireless power delivery, and biosafety monitoring. A fully implantable, wireless, battery-free BCI microsystem is realized as a hybrid PCB assembly (0.33 cm³, 340 mg), with weight and volume reduction achieved through high-Q coil (Q-factor = 157) integration for battery-free operation and hybrid module integration. The ASIC customized chip utilizes capacitive coupling and a pseudo-resistor-based feedback loop for effective DC offset removal and low-frequency signal recording, while also supporting current-mode output for electro-optical multimodal stimulation. Additionally, a 16-bit high-precision temperature sensor enables real-time thermal monitoring, ensuring robust thermal management and mitigating risks of tissue damage. Compared to lightest reported implantable BCI systems, a 66% reduction in weight and an 84% reduction in size are achieved by this design. Benchtop validation and in-situ saline tests confirm the capability of the system for wireless neural signal recording and current stimulation functionality. With a power consumption of 29.7 mW, the temperature rise during 6 hours of continuous operation in an agar-encapsulated simulated tissue environment remains below 0.175°C, effectively preventing thermal damage to surrounding tissue. This microsystem offers a promising platform for investigating neural modulation mechanisms and brain science research in small animals, such as rats and rabbits.

Förderung

  • “Pioneer” and “Leading Goose” Research and Development Program of Zhejiang
  • National Natural Science Foundation of China
  • National Key Research and Development Program of China

Zitieren

APA

Jin, W., Wang, L., Xia, Y., Wang, H., Luo, G., Hong, H., Cheng, Y., Vai, M., Pun, S., & Zheng, N. (2026). A 340-mg Fully Implantable Bidirectional Neuromodulation System Incorporating a Customized ASIC. IEEE Sensors Journal, 26(4), 5697-5709. https://doi.org/10.1109/jsen.2025.3648422

Vancouver

Jin W, Wang L, Xia Y, Wang H, Luo G, Hong H, et al. A 340-mg Fully Implantable Bidirectional Neuromodulation System Incorporating a Customized ASIC. IEEE Sensors Journal. 2026;26(4):5697-5709. doi:10.1109/jsen.2025.3648422

BibTeX
@article{Jin2026,
  author = {Jin, Wenkai and Wang, Liyang and Xia, Yu and Wang, Haochuan and Luo, Guoqing and Hong, Hui and Cheng, Yuhua and Vai, Mang-I and Pun, Sio-Hang and Zheng, Nenggan},
  title = {A 340-mg Fully Implantable Bidirectional Neuromodulation System Incorporating a Customized ASIC},
  journal = {IEEE Sensors Journal},
  year = {2026},
  volume = {26},
  number = {4},
  pages = {5697--5709},
  doi = {10.1109/jsen.2025.3648422}
}
Kostenlos starten →