An Implantable In‐Tube System for Quantitative Precision Vagus Neuromodulation and Feedback of Intestinal Motility
Advanced Materials · 17.11.2026
DOI: 10.1002/adma.75738 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Materials, online erschienen am 17.11.2026. Verfasst von Haoyu Wu und 13 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Hepato-Pancreato-Biliary Surgery, the First Medical Center, Chinese PLA General Hospital, Beijing, China. Die Arbeit nennt 36 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Beijing Natural Science Foundation, Natural Science Foundation of Beijing Municipality.
Abstract (Originalsprache)
Electrical vagus neuromodulation of intestinal motility has demonstrated significant clinical utility in the field, where targeting the brain–gut axis can serve as an adjunct in treating intestinal diseases. However, quantitatively understanding vagus‐intestine interoceptive information about real‐time and in situ feedback on intestinal motility under the influence of electrical stimulation parameters is one of the most urgent challenges. Here we propose an implantable closed‐loop system that combines a scalable catheter‐type ionic piezoelectric (in‐tube) sensor as diverse as the gut, a microelectronic chip, an electrical vagus stimulation electrode, and a display interface to realize point‐of‐care precision vagus neuromodulation and feedback of intestinal motility. Owing to the radial gradient hydrogel structure design and stress concentration effect, the in‐tube sensor can simultaneously quantitatively detect and display four key parameters of intestinal motility, including intensity, frequency, duration, and local compression rate, with a high sensitivity of 7.0 mV mmHg −1 and unique pressure–time integral behavior with a time sensitivity of 24.1 mV s −1 , making up for the deficiency of traditional sensors that cannot obtain pressure duration. After implanting the in‐tube sensor in the anatomically challenging intestinal lumen of rabbits, we intuitively show how electrical vagus stimulation affects intestinal motility, which guides the optimal frequency window of 5 ∼ 10 Hz.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Faculty of Hepato-Pancreato-Biliary Surgery, the First Medical Center, Chinese PLA General Hospital, Beijing, China.
- School of Integrated Circuits and Electronics, Beijing Institute of Technology, Beijing, China.
ORCID-Profile: Haoyu Wu, Zhijian Du, La Li, Zhongyi Duan, Xiangyu Sheng, Guozhen Shen, Kai Jiang
Förderung
- National Natural Science Foundation of China
- Beijing Natural Science Foundation
- Natural Science Foundation of Beijing Municipality
Zitieren
APA
Wu, H., Du, Z., Li, Chen, Z., Liu, W., Duan, Z., Liu, H., Wu, L., Sheng, X., Zhou, L., Yang, K., Chen, D., Shen, G., & Jiang, K. (2026). An Implantable In‐Tube System for Quantitative Precision Vagus Neuromodulation and Feedback of Intestinal Motility. Advanced Materials. https://doi.org/10.1002/adma.75738
Vancouver
Wu H, Du Z, Li, Chen Z, Liu W, Duan Z, et al. An Implantable In‐Tube System for Quantitative Precision Vagus Neuromodulation and Feedback of Intestinal Motility. Advanced Materials. 2026. doi:10.1002/adma.75738
BibTeX
@article{Wu2026,
author = {Wu, Haoyu and Du, Zhijian and Li, La and Chen, Zhongming and Liu, Weijia and Duan, Zhongyi and Liu, Haiqing and Wu, Lifeng and Sheng, Xiangyu and Zhou, Lihao and Yang, Kaiwen and Chen, Di and Shen, Guozhen and Jiang, Kai},
title = {An Implantable In‐Tube System for Quantitative Precision Vagus Neuromodulation and Feedback of Intestinal Motility},
journal = {Advanced Materials},
year = {2026},
doi = {10.1002/adma.75738}
}
EUVIMED