EUVIMEDEUVIMED entdecken
Crossref

Rapid and Efficient Identification of Cd (II) Ions in Water With Functionalized Gold Nanoparticle Coated Etched FBG Sensors

Debojyoti Mondal, B. S. Kavitha, N. Vajresh Kumar, S. Asokan

IEEE Sensors Journal · 15.09.2024 · 24 (18) · 28852-28859

DOI: 10.1109/jsen.2024.3434335 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Sensors Journal, erschienen am 15.09.2024. Verfasst von Debojyoti Mondal und 3 weiteren Autor:innen. Die Arbeit wurde bisher 9-mal zitiert (Crossref). Gefördert von: Department of Science and Technology (DST), Government of India.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cadmium [Cd (II)] is one of the important contributors to global water pollution, due to its prolonged biological half-life and carcinogenic nature. This study presents a selective and sensitive optical sensor based on an etched fiber Bragg grating (e-FBG) sensor coated with mercaptosuccinic acid (MSA) functionalized gold nanoparticles (gnps) for the rapid identification of Cd (II). Carboxylic groups present in MSA self-assembles on gnps to provide the selective binding sites for Cd (II), thereby inducing a Bragg wavelength shift ( $\Delta \lambda _{B}$ ) with corresponding changes in Cd (II) concentrations. This study demonstrates a linear dependence of $\Delta \lambda _{B}$ with the molar concentration of Cd (II), with a limit of detection (LOD) of $10\times 10^{-{15}}{}$ Molar (fM, 0.00000112 ppb) and a dynamic range up to $100\times 10^{-{9}}$ Molar (nM, 11.24 ppb). These values align comfortably with the World Health Organization (WHO) limits ( $26\times 10^{-{9}}$ M or 3 ppb) for drinking water. The specificity of the sensor has been ascertained in the presence of other interfering metal ions such as lead [Pb (II)], mercury [Hg (II)], arsenic [As (III)], sodium [Na (I)], and chromium [Cr (VI)]. Further, the accuracy of the sensor (>93%) has been cross-verified with inductively coupled plasma mass spectroscopy (ICPMS). A good recovery percentage of >95% obtained in drinking water samples further highlights the sensors’ efficacy for practical applications. The linear response, good reproducibility (standard error $\le 15$ pm), portability, and real-time monitoring capability make the present sensor a promising candidate for on-site monitoring of Cd (II) in drinking water samples.

Förderung

  • Department of Science and Technology (DST), Government of India

Zitieren

APA

Mondal, D., Kavitha, B. S., Kumar, N. V., & Asokan, S. (2024). Rapid and Efficient Identification of Cd (II) Ions in Water With Functionalized Gold Nanoparticle Coated Etched FBG Sensors. IEEE Sensors Journal, 24(18), 28852-28859. https://doi.org/10.1109/jsen.2024.3434335

Vancouver

Mondal D, Kavitha BS, Kumar NV, Asokan S. Rapid and Efficient Identification of Cd (II) Ions in Water With Functionalized Gold Nanoparticle Coated Etched FBG Sensors. IEEE Sensors Journal. 2024;24(18):28852-28859. doi:10.1109/jsen.2024.3434335

BibTeX
@article{Mondal2024,
  author = {Mondal, Debojyoti and Kavitha, B. S. and Kumar, N. Vajresh and Asokan, S.},
  title = {Rapid and Efficient Identification of Cd (II) Ions in Water With Functionalized Gold Nanoparticle Coated Etched FBG Sensors},
  journal = {IEEE Sensors Journal},
  year = {2024},
  volume = {24},
  number = {18},
  pages = {28852--28859},
  doi = {10.1109/jsen.2024.3434335}
}
Kostenlos starten →