EUVIMEDEUVIMED entdecken
Crossref

Functionalized Silver Nano Particle Coated e-FBG Sensor for Specific and Rapid Detection of Chromium in Drinking Water

Debojyoti Mondal, B. S. Kavitha, N. Vajresh Kumar, S. Asokan

IEEE Sensors Journal · 15.09.2024 · 24 (18) · 28827-28834

DOI: 10.1109/jsen.2024.3432271 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Sensors Journal, erschienen am 15.09.2024. Verfasst von Debojyoti Mondal und 3 weiteren Autor:innen. Die Arbeit wurde bisher 8-mal zitiert (Crossref). Gefördert von: Department of Science and Technology (DST), Government of India.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Hexavalent chromium [Cr (VI)], a widely used material in industry has raised alarm due to its genotoxicity and carcinogenic nature. This study focuses on developing an effective optical sensor for determining Cr (VI) in drinking water based on polyvinylpyrrolidone (PVP) functionalized silver nanoparticles (AgNp) coated and clad etched Fiber Bragg Grating (e-FBG). The lone pair electrons present in nitrogen (N) and oxygen (O) present in PVP contribute toward the specific binding of Cr (VI) on the sensor surface, causing a shift in the Bragg wavelength ( $\lambda _{\text {B}}$ ) with Cr (VI) concentration. A liner relationship is observed in this study indicating the molar concentration of Cr (VI), with a limit of detection (LOD) of 0.1 pM (0.0000052 ppb), and a working range of 0.1 pM to $100~\mu $ M (5.2 ppm), which is within the World Health Organization (WHO) permissible limit of 960 nM (50 ppb) in drinking water. The sensor is observed to be specific in nature when exposed to other interfering ions like arsenic [As (II)], mercury [Hg (II)], lead [Pb (II)], magnesium [Mg (II)], sodium [Na (I)], and trivalent chromium [Cr (III)]. The sensor’s accuracy has been reconfirmed with inductively coupled plasma mass spectroscopy (ICPMS), which showed an accuracy of (>96%). A good recovery percentage (>95%) for spiked drinking water samples highlights the sensor’s efficacy in the case of real water sample analysis. A portable sensor with real-time monitoring ability, combined with good reproducibility ( ${S} \lt 10$ pM) and liner response, make the present sensor a potential onsite candidate for Cr (VI) determination in drinking water.

Förderung

  • Department of Science and Technology (DST), Government of India

Zitieren

APA

Mondal, D., Kavitha, B. S., Kumar, N. V., & Asokan, S. (2024). Functionalized Silver Nano Particle Coated e-FBG Sensor for Specific and Rapid Detection of Chromium in Drinking Water. IEEE Sensors Journal, 24(18), 28827-28834. https://doi.org/10.1109/jsen.2024.3432271

Vancouver

Mondal D, Kavitha BS, Kumar NV, Asokan S. Functionalized Silver Nano Particle Coated e-FBG Sensor for Specific and Rapid Detection of Chromium in Drinking Water. IEEE Sensors Journal. 2024;24(18):28827-28834. doi:10.1109/jsen.2024.3432271

BibTeX
@article{Mondal2024,
  author = {Mondal, Debojyoti and Kavitha, B. S. and Kumar, N. Vajresh and Asokan, S.},
  title = {Functionalized Silver Nano Particle Coated e-FBG Sensor for Specific and Rapid Detection of Chromium in Drinking Water},
  journal = {IEEE Sensors Journal},
  year = {2024},
  volume = {24},
  number = {18},
  pages = {28827--28834},
  doi = {10.1109/jsen.2024.3432271}
}
Kostenlos starten →