EUVIMEDEUVIMED entdecken
Crossref

Ultrasensitive Measurement of Micronewton Force or Weak Dynamic Signal Based on PDMS Sealed Tapered Fiber Mach–Zehnder Interferometer

Tianzong Xu, Lijun Li, Mengge Xue, Fan Yang, Jie Wang, Zhijie Wen, Qian Ma

IEEE Sensors Journal · 01.03.2024 · 24 (5) · 6240-6250

DOI: 10.1109/jsen.2024.3351998 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Sensors Journal, erschienen am 01.03.2024. Verfasst von Tianzong Xu und 6 weiteren Autor:innen. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 45 Literaturangaben. Gefördert von: Qingdao Feibo Technology Company Ltd., Open Fund Research Project through the State Key Laboratory of Strata Intelligent Control and Green Mining, Shandong Province and the Ministry of Science and Technology.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

An ultrasensitive micronewton force optical sensor based on a tapered fiber Mach–Zehnder interferometer (MZI) embedded in polydimethylsiloxane (PDMS) is studied. Benefited from the methods of nonadiabatic tapering of a fiber combined with mode field mismatch between different fibers, both of which can excite high order modes, the sensor achieves a high sensitivity of up to 0.194 nm/mN and a low detection limit of $103 ~\mu \text{N}$ . Meanwhile, this sensor possesses a longer effective interference length and a narrower free spectral range (FSR) than other microfiber optical sensors, allowing for more traceable intensity dips within the monitoring band. Consequently, a narrower band ( ${C}$ -band) can be employed for monitoring purposes. Additionally, this approach also proves suitable for monitoring the dispersion turning point (DTP) within the ${C}$ -band, and a maximum sensitivity of 0.4091 nm/mN and a low detection limit of $48.9 ~\mu \text{N}$ are obtained. Moreover, owing to its high sensitivity and rapid response time, the sensor can be effectively utilized for real-time monitoring of weak signals, for example, wrist pulse, showing its potential application as a wearable optical sensor in the field of human health monitoring.

Förderung

  • Qingdao Feibo Technology Company Ltd.
  • Open Fund Research Project through the State Key Laboratory of Strata Intelligent Control and Green Mining
  • Shandong Province and the Ministry of Science and Technology
  • Department of Education of Shandong Province
  • Postdoctoral Research Foundation of China
  • Qingdao Feibo Technology Company Ltd

Zitieren

APA

Xu, T., Li, L., Xue, M., Yang, F., Wang, J., Wen, Z., & Ma, Q. (2024). Ultrasensitive Measurement of Micronewton Force or Weak Dynamic Signal Based on PDMS Sealed Tapered Fiber Mach–Zehnder Interferometer. IEEE Sensors Journal, 24(5), 6240-6250. https://doi.org/10.1109/jsen.2024.3351998

Vancouver

Xu T, Li L, Xue M, Yang F, Wang J, Wen Z, et al. Ultrasensitive Measurement of Micronewton Force or Weak Dynamic Signal Based on PDMS Sealed Tapered Fiber Mach–Zehnder Interferometer. IEEE Sensors Journal. 2024;24(5):6240-6250. doi:10.1109/jsen.2024.3351998

BibTeX
@article{Xu2024,
  author = {Xu, Tianzong and Li, Lijun and Xue, Mengge and Yang, Fan and Wang, Jie and Wen, Zhijie and Ma, Qian},
  title = {Ultrasensitive Measurement of Micronewton Force or Weak Dynamic Signal Based on PDMS Sealed Tapered Fiber Mach–Zehnder Interferometer},
  journal = {IEEE Sensors Journal},
  year = {2024},
  volume = {24},
  number = {5},
  pages = {6240--6250},
  doi = {10.1109/jsen.2024.3351998}
}
Kostenlos starten →