EUVIMEDEUVIMED entdecken
Crossref

Noncontact Blood Pressure Estimation With Multispectral Imaging Photoplethysmogram

Jiayu Liu, Kailin Yang, Zhan Shen, Wenyan Wang, Xiaorong Ding

IEEE Internet of Things Journal · 15.06.2026 · 13 (12) · 25843-25853

DOI: 10.1109/jiot.2026.3674224 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Internet of Things Journal, erschienen am 15.06.2026. Verfasst von Jiayu Liu und 4 weiteren Autor:innen. Die Arbeit nennt 26 Literaturangaben. Gefördert von: Huzhou S&T Special Program of Huzhou, National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Imaging photoplethysmography acquired via cameras (RGB, infrared, and so on) holds great promise for vital sign monitoring due to its noncontact and low-cost advantages. Although RGB cameras are ubiquitous in daily life (e.g., smartphones, laptops, and surveillance cameras) and have been utilized for blood pressure (BP) estimation, most existing studies fused multispectral imaging photoplethysmogram (iPPG) (red, green, and blue channels) into a single channel, neglecting the distinct cardiovascular information carried by iPPG of different spectral and from different anatomical regions. To address this gap, this study systematically explores the relationship between multispectral iPPGs (red, green, and blue) and BP and proposes a high-accuracy noncontact BP estimation method. A dataset was constructed using 30 subjects aged 18–35 years old, which have no history of cardiovascular diseases (CVDs), with a mean resting systolic BP (SBP) of $119~\pm ~12$ mmHg and a mean diastolic BP (DBP) of $75~\pm ~9$ mmHg. Data were collected simultaneously via an RGB camera and the CNAP monitor 500 HD under three BP states: rest, controlled deep breathing (DB) at 0.1 Hz, and post-stepping exercise. Based on this dataset, we conducted two studies. The first investigated the correlation between BP and differences in iPPGs across RGB spectral within the same region of interest (ROI) on the forehead measuring $800\times 400$ pixels (single-ROI). The second study examined the relationship between BP and variations in iPPGs for individual RGB spectral bands across distinct anatomical regions, between two adjacent regions on the forehead, each of size $400\times 200$ pixels (dual-ROIs). To quantify the differences between iPPGs, following signal preprocessing, we extracted four types of differential features from the two signals being compared: the difference of the same kind of iPPG features, the difference of different kinds of iPPG features, the difference of the same iPPG fiducial points, and the difference of different kinds of iPPG fiducial points. Pearson correlation coefficient was used for difference features selection, and gradient boosting regression (GBR) is employed with leave-one-out cross-validation (LOOCV) in this study to analyze the association between these difference features and BP. For the single-ROI model, the GBR achieved the accuracy with SBP of $0.01~\pm ~7.41$ mmHg and DBP of $0.05~\pm ~4.38$ mmHg. For the dual-ROI model, the GBR yielded SBP of $- 0.06~\pm ~7.14$ mmHg and DBP of $0.02~\pm ~4.84$ mmHg. Comparative experiments also showed that the proposed method outperformed the single-wavelength iPPG method and the fused iPPG method. This study demonstrates that multispectral iPPGs carry unique BP-related information, providing a novel and effective approach for noncontact BP estimation with improved performance.

Förderung

  • Huzhou S&T Special Program of Huzhou
  • National Natural Science Foundation of China

Zitieren

APA

Liu, J., Yang, K., Shen, Z., Wang, W., & Ding, X. (2026). Noncontact Blood Pressure Estimation With Multispectral Imaging Photoplethysmogram. IEEE Internet of Things Journal, 13(12), 25843-25853. https://doi.org/10.1109/jiot.2026.3674224

Vancouver

Liu J, Yang K, Shen Z, Wang W, Ding X. Noncontact Blood Pressure Estimation With Multispectral Imaging Photoplethysmogram. IEEE Internet of Things Journal. 2026;13(12):25843-25853. doi:10.1109/jiot.2026.3674224

BibTeX
@article{Liu2026,
  author = {Liu, Jiayu and Yang, Kailin and Shen, Zhan and Wang, Wenyan and Ding, Xiaorong},
  title = {Noncontact Blood Pressure Estimation With Multispectral Imaging Photoplethysmogram},
  journal = {IEEE Internet of Things Journal},
  year = {2026},
  volume = {13},
  number = {12},
  pages = {25843--25853},
  doi = {10.1109/jiot.2026.3674224}
}
Kostenlos starten →