EUVIMEDEUVIMED entdecken
Crossref

Leakage Current Measurements of Amorphous Silicon Carbide Encapsulation for Implantable Microelectrode Arrays

Christopher K Nguyen, Alexandra Joshi-Imre, Sandeep Negi, Stuart F Cogan

2024 46th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · 2024

DOI: 10.1109/embc53108.2024.10782884 ↗

Kurz gefasst

Fachartikel in der Zeitschrift 2024 46th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2024. Verfasst von Christopher K Nguyen und 3 weiteren Autor:innen. Hauptthemen laut MEDLINE: Silicon Compounds, Carbon Compounds, Inorganic, Electrodes, Implanted. Die Arbeit nennt 15 Literaturangaben. Gefördert von: NIDCD NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Advancements in implantable microelectrode arrays (MEAs) for neural applications are hindered by challenges in maintaining long-term stability within the body. Amorphous silicon carbide (a-SiC), recognized for its chemical inertness and biocompatibility, emerges as a promising material to address these challenges. Our findings demonstrate that IDEs with a-SiC exhibit high electrical insulation on the order of TΩ emphasizing its potential for enhancing encapsulation reliability. The primary objective of this research is to develop a methodology for evaluating the encapsulation effectiveness of a-SiC under electrical stress. Utilizing interdigitated electrodes (IDEs), the research applies a non-thermal, voltage-driven approach to assess a-SiC's encapsulation. The resistance of a-SiC encapsulated IDEs, crucial for implantable device functionality, is analyzed through this process. This approach not only reinforces the understanding of a-SiC as a viable material for MEAs and identifies an electrical methodology particularly suitable for evaluating implantable encapsulation.Clinical Relevance-This study developed a methodology for measuring leakage current in a-SiC encapsulation, which can be implemented for voltage-driven accelerated testing of implantable microelectrode arrays.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Silicon CompoundsCarbon Compounds, InorganicElectrodes, ImplantedMicroelectrodesEquipment Design

Substanzen

Silicon Compoundssilicon carbideCarbon Compounds, Inorganic

Förderung

  • NIDCD NIH HHS

Zitieren

APA

Nguyen, C. K., Joshi-Imre, A., Negi, S., & Cogan, S. F. (2024). Leakage Current Measurements of Amorphous Silicon Carbide Encapsulation for Implantable Microelectrode Arrays. 2024 46th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC). https://doi.org/10.1109/embc53108.2024.10782884

Vancouver

Nguyen CK, Joshi-Imre A, Negi S, Cogan SF. Leakage Current Measurements of Amorphous Silicon Carbide Encapsulation for Implantable Microelectrode Arrays. 2024 46th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC). 2024. doi:10.1109/embc53108.2024.10782884

BibTeX
@article{Nguyen2024,
  author = {Nguyen, Christopher K and Joshi-Imre, Alexandra and Negi, Sandeep and Cogan, Stuart F},
  title = {Leakage Current Measurements of Amorphous Silicon Carbide Encapsulation for Implantable Microelectrode Arrays},
  journal = {2024 46th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)},
  year = {2024},
  doi = {10.1109/embc53108.2024.10782884}
}
Kostenlos starten →