Urban Solar Harvesting With Cylindrical Solar Cells: Field Performance and Optimal Installation
IEEE Access · 2026 · 14 · 89914-89933
DOI: 10.1109/access.2026.3702690 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Access, 2026. Verfasst von Kento Honma und 4 weiteren Autor:innen. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for the Promotion of Science KAKENHI.
Abstract (Originalsprache)
Building-integrated urban solar power generation increasingly uses conventional flat-plate modules, which are highly sensitive to incident angles, experience shading, and operate at elevated temperatures. Cylindrical solar cells enable omnidirectional light collection and facilitate natural cooling; however, their outdoor performance and optimal fixed installation conditions are insufficiently quantified. The electrical and thermal behavior of cylindrical solar cells under urban outdoor conditions was analyzed through field measurements, regression-based performance modeling, and comparative thermal analysis with a flat-plate module. Using the independently evaluated regression-model structure refitted to the full screened dataset, a representative clear-sky-day-based cumulative energy index, rather than a realistic full-year yield, was estimated under fixed installation constraints for wall-mounted and rooftop applications. The results show that solar irradiance and incidence geometry determine maximum power generation, while surface temperature is important but secondary. The model was tested using independent hold-out and leave-one-day-out cross-validation. In the independent test dataset, the regression model incorporating irradiance, incidence descriptors, and surface temperature maintained predictive capability, with R ${}^{2} =0.83$ and RMSE = 2.74 W. The cylindrical module operated at lower temperatures than the flat-plate module, with a maximum temperature difference of $21.1~^{\circ }$ C. Using a common representative temperature coefficient, temperature-induced power reductions at 12:00 were estimated at 6.0% for the cylindrical module and 16.5% for the flat-plate module relative to the $25~^{\circ }$ C reference condition. A 45° east–west-oriented rooftop installation maximizes the representative clear-sky-day cumulative energy index, whereas vertical wall-mounted configurations showed a trade-off between cumulative index value and seasonal stability.
Förderung
- Japan Society for the Promotion of Science KAKENHI
Zitieren
APA
Honma, K., Tamura, F., Nakamura, M., Hayase, S., & Yokogawa, S. (2026). Urban Solar Harvesting With Cylindrical Solar Cells: Field Performance and Optimal Installation. IEEE Access, 14, 89914-89933. https://doi.org/10.1109/access.2026.3702690
Vancouver
Honma K, Tamura F, Nakamura M, Hayase S, Yokogawa S. Urban Solar Harvesting With Cylindrical Solar Cells: Field Performance and Optimal Installation. IEEE Access. 2026;14:89914-89933. doi:10.1109/access.2026.3702690
BibTeX
@article{Honma2026,
author = {Honma, Kento and Tamura, Fumiki and Nakamura, Masaki and Hayase, Shuzi and Yokogawa, Shinji},
title = {Urban Solar Harvesting With Cylindrical Solar Cells: Field Performance and Optimal Installation},
journal = {IEEE Access},
year = {2026},
volume = {14},
pages = {89914--89933},
doi = {10.1109/access.2026.3702690}
}
EUVIMED