Assessing protein-specific radiation damage in time-resolved X-ray solution-scattering experiments at high-brilliance synchrotrons using fast detector readout
Acta Crystallographica Section D Structural Biology · 01.07.2026 · 82 (7) · 715-726
DOI: 10.1107/s2059798326005164 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta Crystallographica Section D Structural Biology, online erschienen am 12.06.2026. Verfasst von Fatemeh Sabzian-Molaei und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Umeå University, Umeå, Sweden. Hauptthemen laut MEDLINE: X-Ray Diffraction, Synchrotrons, Adenylate Kinase. Die Arbeit nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Vetenskapsrådet, Kempestiftelserna, H2020 Marie Skłodowska-Curie Actions.
Abstract (Originalsprache)
Time-resolved X-ray solution scattering (TR-XSS) enables tracking of protein structural dynamics but can suffer from radiation damage when performed with continuous X-ray beam exposure at multipurpose small-angle X-ray scattering (SAXS) beamlines. Here, we systematically assess how protein concentration, exposure time, X-ray dose and beam focusing influence the stability of adenylate kinase (AdK) during TR-XSS at CoSAXS at the MAX IV Laboratory. Static SAXS measurements from 2.5 to 21 mg ml −1 showed only minor interparticle effects, establishing suitable concentrations for TR-XSS. Under detector-focused conditions, AdK irradiated at room temperature remained stable up to 3.13 kGy, with consistent absolute and difference scattering profiles over 50 ms. In contrast, focusing the beam directly on the sample increased the absorbed dose to 21.3 kGy and produced clear signatures of radiation damage, which included low- q intensity loss and increasing deviation from the low-dose condition. These results identify practical system-specific dose limits and highlight beam focusing as a key determinant of sample integrity. The workflow presented here provides general guidelines for minimizing radiation artifacts in TR-XSS on multipurpose SAXS beamlines.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, Umeå University, Umeå, Sweden.
- MAX IV Laborator, Lund University, Lund, Sweden.
ORCID-Profile: Fatemeh Sabzian-Molaei, Tomás S Plivelic
Förderung
- Vetenskapsrådet
- Kempestiftelserna
- H2020 Marie Skłodowska-Curie Actions
- VINNOVA
- Svenska Forskningsrådet Formas
Zitieren
APA
Sabzian-Molaei, F., Plivelic, T. S., & Andersson, M. (2026). Assessing protein-specific radiation damage in time-resolved X-ray solution-scattering experiments at high-brilliance synchrotrons using fast detector readout. Acta Crystallographica Section D Structural Biology, 82(7), 715-726. https://doi.org/10.1107/s2059798326005164
Vancouver
Sabzian-Molaei F, Plivelic TS, Andersson M. Assessing protein-specific radiation damage in time-resolved X-ray solution-scattering experiments at high-brilliance synchrotrons using fast detector readout. Acta Crystallographica Section D Structural Biology. 2026;82(7):715-726. doi:10.1107/s2059798326005164
BibTeX
@article{SabzianMolaei2026,
author = {Sabzian-Molaei, Fatemeh and Plivelic, Tomás S and Andersson, Magnus},
title = {Assessing protein-specific radiation damage in time-resolved X-ray solution-scattering experiments at high-brilliance synchrotrons using fast detector readout},
journal = {Acta Crystallographica Section D Structural Biology},
year = {2026},
volume = {82},
number = {7},
pages = {715--726},
doi = {10.1107/s2059798326005164}
}
EUVIMED