Adaptable SEC‐SAXS data collection for higher quality structure analysis in solution
Protein Science · 2024
DOI: 10.1002/pro.4946 ↗Kurz gefasst
Fachartikel in der Zeitschrift Protein Science, 2024. Verfasst von Tsutomu Matsui und 4 weiteren Autor:innen. Beteiligte Einrichtung: Stanford Synchrotron Radiation Lightsource, SLAC National Accelerator Laboratory, Menlo Park, California, USA. Hauptthemen laut MEDLINE: Synchrotrons. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIH HHS, NIGMS NIH HHS, NCI NIH HHS.
Abstract (Originalsprache)
The two major challenges in synchrotron size‐exclusion chromatography coupled in‐line with small‐angle x‐ray scattering (SEC‐SAXS) experiments are the overlapping peaks in the elution profile and the fouling of radiation‐damaged materials on the walls of the sample cell. In recent years, many post‐experimental analyses techniques have been developed and applied to extract scattering profiles from these problematic SEC‐SAXS data. Here, we present three modes of data collection at the BioSAXS Beamline 4–2 of the Stanford Synchrotron Radiation Lightsource (SSRL BL4‐2). The first mode, the High‐Resolution mode, enables SEC‐SAXS data collection with excellent sample separation and virtually no additional peak broadening from the UHPLC UV detector to the x‐ray position by taking advantage of the low system dispersion of the UHPLC. The small bed volume of the analytical SEC column minimizes sample dilution in the column and facilitates data collection at higher sample concentrations with excellent sample economy equal to or even less than that of the conventional equilibrium SAXS method. Radiation damage problems during SEC‐SAXS data collection are evaded by additional cleaning of the sample cell after buffer data collection and avoidance of unnecessary exposures through the use of the x‐ray shutter control options, allowing sample data collection with a clean sample cell. Therefore, accurate background subtraction can be performed at a level equivalent to the conventional equilibrium SAXS method without requiring baseline correction, thereby leading to more reliable downstream structural analysis and quicker access to new science. The two other data collection modes, the High‐Throughput mode and the Co‐Flow mode, add agility to the planning and execution of experiments to efficiently achieve the user's scientific objectives at the SSRL BL4‐2.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Stanford Synchrotron Radiation Lightsource, SLAC National Accelerator Laboratory, Menlo Park, California, USA.
- Department of Biochemistry and Physiology, University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, USA.
- Stephenson Cancer Center, University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, USA.
- Laboratory of Biomolecular Structure and Function, University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, USA.
ORCID-Profile: Tsutomu Matsui, Ivan Rajkovic, Blaine H M Mooers, Ping Liu, Thomas M Weiss
Förderung
- NIH HHS
- NIGMS NIH HHS
- NCI NIH HHS
- U.S. Department of Energy
- National Institute of General Medical Sciences
- National Institutes of Health
- Stephenson Cancer Center
Zitieren
APA
Matsui, T., Rajkovic, I., Mooers, B. H. M., Liu, P., & Weiss, T. M. (2024). Adaptable SEC‐SAXS data collection for higher quality structure analysis in solution. Protein Science. https://doi.org/10.1002/pro.4946
Vancouver
Matsui T, Rajkovic I, Mooers BHM, Liu P, Weiss TM. Adaptable SEC‐SAXS data collection for higher quality structure analysis in solution. Protein Science. 2024. doi:10.1002/pro.4946
BibTeX
@article{Matsui2024,
author = {Matsui, Tsutomu and Rajkovic, Ivan and Mooers, Blaine H M and Liu, Ping and Weiss, Thomas M},
title = {Adaptable SEC‐SAXS data collection for higher quality structure analysis in solution},
journal = {Protein Science},
year = {2024},
doi = {10.1002/pro.4946}
}
EUVIMED