EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

SiC resistive X-ray beam monitor for intensity and position control of synchrotron light

Gabriele Trovato iD, Niccolò La Rosa iD, Francesco La Via, Janin Lubeck iD, Antonio Manno, Samuele Moscato iD, Matthias Müller iD, Massimo Camarda

Journal of Synchrotron Radiation · 01.07.2026 · 33 (4) · 995-1004

DOI: 10.1107/s1600577526005242 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Synchrotron Radiation, online erschienen am 18.06.2026. Verfasst von Gabriele Trovato und 7 weiteren Autor:innen. Beteiligte Einrichtung: Università degli Studi di Catania, Dipartimento di Fisica e Astronomia `Ettore Majorana', Via Santa Sofia 64, 95123 Catania, Italy. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministero dell'Università e della Ricerca, SAMOTHRACE project, Horizon 2020 Framework Programme.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A silicon carbide (SiC) X-ray beam position monitor is presented, based on a resistive charge-division principle derived from lateral-effect photodiodes and specifically adapted for synchrotron radiation applications. This device, referred to as a resistive X-ray beam position monitor (rXBPM), exploits a free-standing SiC membrane combined with a resistive p + -doped layer, enabling transmission-mode operation while preserving high radiation hardness and mechanical robustness. In contrast to conventional segmented X-ray beam position monitors, whose response depends strongly on the beam spot size and is typically limited to narrow linear regions, the resistive architecture of the rXBPM provides an intrinsically beam-footprint-independent position signal with an extended linear response region. The detector was fabricated using selective electrochemical etching to realize a thin membrane structure and was experimentally characterized at the microfocus beamline (MiFo) in the PTB laboratory at the BESSY II synchrotron facility using 5.4 keV X-rays. An average transmission of approximately 61% was measured, with good spatial uniformity across the membrane area. Raster-scan measurements demonstrate a linear position response over ranges of ±500 µm and ±1 mm around the detector center, with position sensitivities exceeding 0.157 mm −1 and estimated upper-limit noise-equivalent positions of a few micrometres. Three-dimensional COMSOL simulations were used to model charge transport and lateral charge division in the real device geometry, showing excellent agreement with experimental results and confirming the independence of the position sensitivity from the beam spot size over a wide range of operating conditions. These results establish SiC rXBPMs as a compact, beam spot size calibration-free and radiation-hard solution for beam diagnostics at modern synchrotron light sources, with particular relevance for applications requiring large active areas, extended linearity and minimal beam perturbation.

Schlagwörter

Stichwörter der Autor:innen

X-ray position monitoringbeamline diagnostic elementfree-standing membranelateral effect photodiode (LEP)silicon carbide

Autor:innen und Institutionen

  • Università degli Studi di Catania, Dipartimento di Fisica e Astronomia `Ettore Majorana', Via Santa Sofia 64, 95123 Catania, Italy.
  • STLab srl, Via Anapo 53, 95126 Catania, Italy.
  • Istituto Nazionale di Fisica Nucleare - INFN, Sezione di Catania, Via S. Sofia 64, 95123 Catania, Italy.
  • Istituto per la Microelettronica e Microsistemi CNR-IMM, Sezione di Catania, Strada VIII Zona Industriale 5, 95121 Catania, Italy.
  • Università degli Studi di Catania, Dipartimento di Ingegneria Elettrica, Elettronica e Informatica (DIEEI), Viale Andrea Doria 6, I-95125 Catania, Italy.
  • Physikalisch-Technische Bundesanstalt (PTB), Abbestraße 2-12, 10587 Berlin, Germany.

ORCID-Profile: Gabriele Trovato, Niccolò La Rosa, Janin Lubeck, Samuele Moscato, Matthias Müller

Förderung

  • Ministero dell'Università e della Ricerca
  • SAMOTHRACE project
  • Horizon 2020 Framework Programme

Zitieren

APA

Trovato, G., La Rosa, N., La Via, F., Lubeck, J., Manno, A., Moscato, S., Müller, M., & Camarda, M. (2026). SiC resistive X-ray beam monitor for intensity and position control of synchrotron light. Journal of Synchrotron Radiation, 33(4), 995-1004. https://doi.org/10.1107/s1600577526005242

Vancouver

Trovato G, La Rosa N, La Via F, Lubeck J, Manno A, Moscato S, et al. SiC resistive X-ray beam monitor for intensity and position control of synchrotron light. Journal of Synchrotron Radiation. 2026;33(4):995-1004. doi:10.1107/s1600577526005242

BibTeX
@article{Trovato2026,
  author = {Trovato, Gabriele and La Rosa, Niccolò and La Via, Francesco and Lubeck, Janin and Manno, Antonio and Moscato, Samuele and Müller, Matthias and Camarda, Massimo},
  title = {SiC resistive X-ray beam monitor for intensity and position control of synchrotron light},
  journal = {Journal of Synchrotron Radiation},
  year = {2026},
  volume = {33},
  number = {4},
  pages = {995--1004},
  doi = {10.1107/s1600577526005242}
}