Hard X-ray imaging and tomography at the Biomedical Imaging and Therapy beamlines of Canadian Light Source
Journal of Synchrotron Radiation · 01.09.2024 · 31 (5) · 1346-1357
DOI: 10.1107/s1600577524005241 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Synchrotron Radiation, online erschienen am 15.07.2024. Verfasst von Sergey Gasilov und 7 weiteren Autor:innen. Beteiligte Einrichtung: Canadian Light Source, 44 Innovation Boulevard, Saskatoon S7N 2V3, Canada. Hauptthemen laut MEDLINE: Synchrotrons. Die Arbeit wurde bisher 34-mal zitiert (Crossref) und nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Canada Foundation for Innovation, Natural Sciences and Engineering Research Council of Canada, National Research Council Canada.
Abstract (Originalsprache)
The Biomedical Imaging and Therapy facility of the Canadian Light Source comprises two beamlines, which together cover a wide X-ray energy range from 13 keV up to 140 keV. The beamlines were designed with a focus on synchrotron applications in preclinical imaging and veterinary science as well as microbeam radiation therapy. While these remain a major part of the activities of both beamlines, a number of recent upgrades have enhanced the versatility and performance of the beamlines, particularly for high-resolution microtomography experiments. As a result, the user community has been quickly expanding to include researchers in advanced materials, batteries, fuel cells, agriculture, and environmental studies. This article summarizes the beam properties, describes the endstations together with the detector pool, and presents several application cases of the various X-ray imaging techniques available to users.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Canadian Light Source, 44 Innovation Boulevard, Saskatoon S7N 2V3, Canada.
- College of Medicine, University of Saskatchewan, 107 Wiggins Road, Saskatoon S7N 5E5, Canada.
ORCID-Profile: M Adam Webb, Arash Panahifar, David M L Cooper
Förderung
- Canada Foundation for Innovation
- Natural Sciences and Engineering Research Council of Canada
- National Research Council Canada
- Canadian Institutes of Health Research
- Government of Saskatchewan
- University of Saskatchewan
Zitieren
APA
Gasilov, S., Webb, M. A., Panahifar, A., Zhu, N., Marinos, O., Bond, T., Cooper, D. M. L., & Chapman, D. (2024). Hard X-ray imaging and tomography at the Biomedical Imaging and Therapy beamlines of Canadian Light Source. Journal of Synchrotron Radiation, 31(5), 1346-1357. https://doi.org/10.1107/s1600577524005241
Vancouver
Gasilov S, Webb MA, Panahifar A, Zhu N, Marinos O, Bond T, et al. Hard X-ray imaging and tomography at the Biomedical Imaging and Therapy beamlines of Canadian Light Source. Journal of Synchrotron Radiation. 2024;31(5):1346-1357. doi:10.1107/s1600577524005241
BibTeX
@article{Gasilov2024,
author = {Gasilov, Sergey and Webb, M Adam and Panahifar, Arash and Zhu, Ning and Marinos, Omar and Bond, Toby and Cooper, David M L and Chapman, Dean},
title = {Hard X-ray imaging and tomography at the Biomedical Imaging and Therapy beamlines of Canadian Light Source},
journal = {Journal of Synchrotron Radiation},
year = {2024},
volume = {31},
number = {5},
pages = {1346--1357},
doi = {10.1107/s1600577524005241}
}
EUVIMED