Structural properties in ruptured mitral chordae tendineae measured by synchrotron-based X-ray phase computed tomography
Journal of Synchrotron Radiation · 2023
DOI: 10.1107/s1600577523005167 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Synchrotron Radiation, 2023. Verfasst von Yojiro Koda und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, Division of Cardiovascular Surgery, Kobe University Hospital, Kobe, Japan. Hauptthemen laut MEDLINE: Mitral Valve, Mitral Valve Insufficiency. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society of the Promotion of Science.
Abstract (Originalsprache)
The link between the structural properties and the rupturing of chordae tendineae in the mitral valve complex is still unclear. Synchrotron-radiation-based X-ray phase computed tomography (SR-XPCT) imaging is an innovative way to quantitatively analyze three-dimensional morphology. XPCT has been employed in this study to evaluate the chordae tendineae from patients with mitral regurgitation and to analyze structural changes in the ruptured chordae tendineae in patients with this condition. Six ruptured mitral chordae tendineae were obtained during surgical repairs for mitral regurgitation and were fixed with formalin. In addition, 12 healthy chordae tendineae were obtained from autopsies. Employing XPCT (effective pixel size, 3.5 µm; density resolution, 1 mg cm −3 ), the density of the chordae tendineae in each sample was measured. The specimens were subsequently analyzed pathologically. The mean age was 70.2 ± 3.0 in the rupture group and 67.2 ± 14.1 years old in the control group ( p = 0.4927). All scans of chorda tendineae with SR-XPCT were performed successfully. The mean densities were 1.029 ± 0.004 in the rupture group and 1.085 ± 0.015 g cm −3 in the control group ( p < 0.0001). Density based on SR-XPCT in the ruptured mitral chordae tendineae was significantly lower compared with the healthy chorda tendinea. Histological examination revealed a change in the components of the connective tissues in ruptured chorda tendinea, in accordance with the low density measured by SR-XPCT. SR-XPCT made it possible to measure tissue density in mitral chordae tendineae. Low density in mitral chordae tendineae is associated with a greater fragility in ruptured mitral chordae tendineae.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Surgery, Division of Cardiovascular Surgery, Kobe University Hospital, Kobe, Japan.
- Scattering and Imaging Division, Japan Synchrotron Radiation Research Institute, Sayo, Japan.
- Department of Pathology, Hokusetsu General Hospital, Takatsuki, Osaka, Japan.
ORCID-Profile: Takuro Tsukube, Masato Hoshino, Naoto Yagi
Förderung
- Japan Society of the Promotion of Science
Zitieren
APA
Koda, Y., Tsukube, T., Hoshino, M., Yagi, N., Ishibashi-Ueda, H., & Okada, K. (2023). Structural properties in ruptured mitral chordae tendineae measured by synchrotron-based X-ray phase computed tomography. Journal of Synchrotron Radiation. https://doi.org/10.1107/s1600577523005167
Vancouver
Koda Y, Tsukube T, Hoshino M, Yagi N, Ishibashi-Ueda H, Okada K. Structural properties in ruptured mitral chordae tendineae measured by synchrotron-based X-ray phase computed tomography. Journal of Synchrotron Radiation. 2023. doi:10.1107/s1600577523005167
BibTeX
@article{Koda2023,
author = {Koda, Yojiro and Tsukube, Takuro and Hoshino, Masato and Yagi, Naoto and Ishibashi-Ueda, Hatsue and Okada, Kenji},
title = {Structural properties in ruptured mitral chordae tendineae measured by synchrotron-based X-ray phase computed tomography},
journal = {Journal of Synchrotron Radiation},
year = {2023},
doi = {10.1107/s1600577523005167}
}
EUVIMED