EUVIMEDOpdag EUVIMED
Crossref

Advanced LIGO detector performance in the fourth observing run

E. Capote, W. Jia, N. Aritomi, M. Nakano, V. Xu, R. Abbott, I. Abouelfettouh, R. X. Adhikari, A. Ananyeva, S. Appert, S. K. Apple, K. Arai and 28 more

Physical Review D · 2025-03-03 · 111 (6)

DOI: 10.1103/physrevd.111.062002 ↗

At a glance

Journal article in Physical Review D, published online on 2025-03-03. Written by E. Capote and 39 co-authors. Cited 147 times so far (Crossref); 113 references. Funded by: National Science Foundation, Science and Technology Facilities Council, Max-Planck-Gesellschaft.

AbstractBibliografiske oplysningerCiteRelated studies

Abstract (original language)

On May 24th, 2023, the Advanced Laser Interferometer Gravitational-Wave Observatory (LIGO), joined by the Advanced Virgo and KAGRA detectors, began the fourth observing run for a two-year-long dedicated search for gravitational waves. The LIGO Hanford and Livingston detectors have achieved an unprecedented sensitivity to gravitational waves, with an angle-averaged median range to binary neutron star mergers of 152 Mpc and 160 Mpc, and duty cycles of 65.0% and 71.2%, respectively, with a coincident duty cycle of 52.6%. The maximum range achieved by the LIGO Hanford detector is 165 Mpc and the LIGO Livingston detector 177 Mpc, both achieved during the second part of the fourth observing run. For the fourth run, the quantum-limited sensitivity of the detectors was increased significantly due to the higher intracavity power from laser system upgrades and replacement of core optics, and from the addition of a 300 m filter cavity to provide the squeezed light with a frequency-dependent squeezing angle, part of the A+ upgrade program. Altogether, the A+ upgrades led to reduced detector-wide losses for the squeezed vacuum states of light which, alongside the filter cavity, enabled broadband quantum noise reduction of up to 5.2 dB at the Hanford observatory and 6.1 dB at the Livingston observatory. Improvements to sensors and actuators as well as significant controls commissioning increased low frequency sensitivity. This paper details these instrumental upgrades, analyzes the noise sources that limit detector sensitivity, and describes the commissioning challenges of the fourth observing run.

Funding

  • National Science Foundation
  • Science and Technology Facilities Council
  • Max-Planck-Gesellschaft
  • Australian Research Council
  • California Institute of Technology
  • Massachusetts Institute of Technology

Cite

APA

Capote, E., Jia, W., Aritomi, N., Nakano, M., Xu, V., Abbott, R., Abouelfettouh, I., Adhikari, R. X., Ananyeva, A., Appert, S., Apple, S. K., Arai, K., Aston, S. M., Ball, M., Ballmer, S. W., Barker, D., Barsotti, L., Berger, B. K., Betzwieser, J., …, & Cumming, A. (2025). Advanced LIGO detector performance in the fourth observing run. Physical Review D, 111(6). https://doi.org/10.1103/physrevd.111.062002

Vancouver

Capote E, Jia W, Aritomi N, Nakano M, Xu V, Abbott R, et al. Advanced LIGO detector performance in the fourth observing run. Physical Review D. 2025;111(6). doi:10.1103/physrevd.111.062002

BibTeX
@article{Capote2025,
  author = {Capote, E. and Jia, W. and Aritomi, N. and Nakano, M. and Xu, V. and Abbott, R. and Abouelfettouh, I. and Adhikari, R. X. and Ananyeva, A. and Appert, S. and Apple, S. K. and Arai, K. and Aston, S. M. and Ball, M. and Ballmer, S. W. and Barker, D. and Barsotti, L. and Berger, B. K. and Betzwieser, J. and Bhattacharjee, D. and Billingsley, G. and Biscans, S. and Blair, C. D. and Bode, N. and Bonilla, E. and Bossilkov, V. and Branch, A. and Brooks, A. F. and Brown, D. D. and Bryant, J. and Cahillane, C. and Cao, H. and Clara, F. and Collins, J. and Compton, C. M. and Cottingham, R. and Coyne, D. C. and Crouch, R. and Csizmazia, J. and Cumming, A.},
  title = {Advanced LIGO detector performance in the fourth observing run},
  journal = {Physical Review D},
  year = {2025},
  volume = {111},
  number = {6},
  doi = {10.1103/physrevd.111.062002}
}
Start for free →