Low frequency, 100–600 MHz, searches with axion cavity haloscopes
Physical Review D · 16.02.2024 · 109 (4)
DOI: 10.1103/physrevd.109.042004 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physical Review D, online erschienen am 16.02.2024. Verfasst von S. Chakrabarty und 39 weiteren Autor:innen. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 63 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: U.S. Department of Energy, Fermilab, Heising-Simons Foundation.
Abstract (Originalsprache)
We investigate reentrant and dielectric loaded cavities for the purpose of extending the range of axion cavity haloscopes to lower masses, below the range where the Axion Dark Matter experiment (ADMX) has already searched. Reentrant and dielectric loaded cavities were simulated numerically to calculate and optimize their form factors and quality factors. A prototype reentrant cavity was built and its measured properties were compared with the simulations. We estimate the sensitivity of axion dark matter searches using reentrant and dielectric loaded cavities inserted in the existing ADMX magnet at the University of Washington and a large magnet being installed at Fermilab. Published by the American Physical Society 2024
Förderung
- U.S. Department of Energy
- Fermilab
- Heising-Simons Foundation
- Lawrence Livermore National Laboratory
- Pacific Northwest National Laboratory
- Battelle
- Australian Research Council
- Forrest Research Foundation
Zitieren
APA
Chakrabarty, S., Gleason, J. R., Han, Y., Hipp, A. T., Solano, M., Sikivie, P., Sullivan, N. S., Tanner, D. B., Goryachev, M., Hartman, E., McAllister, B. T., Quiskamp, A., Thomson, C., Tobar, M. E., Awida, M. H., Chou, A. S., Hollister, M., Knirck, S., Sonnenschein, A., …, & Daw, E. J. (2024). Low frequency, 100–600 MHz, searches with axion cavity haloscopes. Physical Review D, 109(4). https://doi.org/10.1103/physrevd.109.042004
Vancouver
Chakrabarty S, Gleason JR, Han Y, Hipp AT, Solano M, Sikivie P, et al. Low frequency, 100–600 MHz, searches with axion cavity haloscopes. Physical Review D. 2024;109(4). doi:10.1103/physrevd.109.042004
BibTeX
@article{Chakrabarty2024,
author = {Chakrabarty, S. and Gleason, J. R. and Han, Y. and Hipp, A. T. and Solano, M. and Sikivie, P. and Sullivan, N. S. and Tanner, D. B. and Goryachev, M. and Hartman, E. and McAllister, B. T. and Quiskamp, A. and Thomson, C. and Tobar, M. E. and Awida, M. H. and Chou, A. S. and Hollister, M. and Knirck, S. and Sonnenschein, A. and Wester, W. and Braine, T. and Guzzetti, M. and Hanretty, C. and Leum, G. and Rosenberg, L. J and Rybka, G. and Sinnis, J. and Clarke, John and Siddiqi, I. and Khatiwada, R. and Carosi, G. and Du, N. and Robertson, N. and Duffy, L. D. and Boutan, C. and Oblath, N. S. and Taubman, M. S. and Yang, J. and Lentz, E. and Daw, E. J.},
title = {Low frequency, 100–600 MHz, searches with axion cavity haloscopes},
journal = {Physical Review D},
year = {2024},
volume = {109},
number = {4},
doi = {10.1103/physrevd.109.042004}
}
EUVIMED