EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Resonant heterodyne conversion applied to a low-frequency haloscope for dark matter axion searches in the 1–35 MHz range

Jose R. Navarro-Madrid, José Reina-Valero, Alejandro Díaz-Morcillo, Benito Gimeno

Physical Review D · 03.11.2026 · 114 (9)

DOI: 10.1103/lr59-b552 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physical Review D, online erschienen am 03.11.2026. Verfasst von Jose R. Navarro-Madrid und 3 weiteren Autor:innen. Die Arbeit nennt 104 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministerio de Ciencia e Innovación, Agencia Estatal de Investigación, European Regional Development Fund.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

We study resonant heterodyne up conversion in the RADES-BabyIAXO haloscope as a method to search for low-mass dark matter axions using microwave cavities. Starting from axion electrodynamics, we derive the axion-induced source term and the power extracted through a readout mode, explicitly accounting for the finite axion linewidth. This leads to effective quality factors that determine the pump-axion mixing, detection bandwidth, and detected signal power. We extend the BI-RME 3D full-wave formulation to heterodyne axion detection in a realistic two-port cavity, including pump leakage into the readout channel. Applying the formalism to the largest RADES-BabyIAXO cavity identifies the quasi − TE 011 − quasi − TM 010 mode pair as a favorable configuration, enabling sensitivity to axion frequencies between 0.9 and 34.6 MHz. Analytical and full-wave predictions show excellent agreement at resonance, while the full-wave model provides a more accurate description off resonance and allows a precise characterization of the pump leakage. We also derive the optimal port couplings that maximize the scanning rate. Upper-limit sensitivity for cryogenic copper and superconducting niobium cavities indicate that, under thermal-noise-limited conditions and assuming sufficient pump-leakage rejection, the experiment could probe axion-photon couplings down to 10 − 15 GeV − 1 at 90% confidence level, representing a significant improvement over previous heterodyne-based searches.

Förderung

  • Ministerio de Ciencia e Innovación
  • Agencia Estatal de Investigación
  • European Regional Development Fund
  • European Commission
  • European Research Council
  • Universidad Politécnica de Cartagena
  • Conselleria de Innovación, Universidades, Ciencia y Sociedad Digital, Generalitat Valenciana
  • NextGenerationEU

Zitieren

APA

Navarro-Madrid, J. R., Reina-Valero, J., Díaz-Morcillo, A., & Gimeno, B. (2026). Resonant heterodyne conversion applied to a low-frequency haloscope for dark matter axion searches in the 1–35 MHz range. Physical Review D, 114(9). https://doi.org/10.1103/lr59-b552

Vancouver

Navarro-Madrid JR, Reina-Valero J, Díaz-Morcillo A, Gimeno B. Resonant heterodyne conversion applied to a low-frequency haloscope for dark matter axion searches in the 1–35 MHz range. Physical Review D. 2026;114(9). doi:10.1103/lr59-b552

BibTeX
@article{NavarroMadrid2026,
  author = {Navarro-Madrid, Jose R. and Reina-Valero, José and Díaz-Morcillo, Alejandro and Gimeno, Benito},
  title = {Resonant heterodyne conversion applied to a low-frequency haloscope for dark matter axion searches in the 1–35 MHz range},
  journal = {Physical Review D},
  year = {2026},
  volume = {114},
  number = {9},
  doi = {10.1103/lr59-b552}
}
Kostenlos starten →