EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Implementation of a passive bi-articular ankle–knee exoskeleton during maximal squat jumping

Logan Wade iD, Glen Lichtwark iD, Dominic Farris iD

Royal Society Open Science · 2024-07 · 11 (7)

DOI: 10.1098/rsos.240390 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Royal Society Open Science, online erschienen am 31.07.2024. Verfasst von Logan Wade und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department for Health, University of Bath, Bath, UK. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Australian Government.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Owing to the unexplored potential to harness knee extension power during jumping, the current study aimed to examine how joint mechanics were altered with a biologically inspired, passive bi-articular ankle–knee exoskeleton, which could potentially facilitate greater jump height by increasing work production about the knee and ankle. Twenty-five participants (16 males and 9 females, 175.2 ± 8.2 cm, 72.9 ± 10.3 kg, 24.0 ± 3.4 years) performed maximal squat jumping with and without the exoskeletal device and we compared jump height, joint moment and joint work of the lower limbs. Despite a low exoskeleton stiffness and therefore a limited capacity to store energy, the bi-articular device resulted in decreased jump height (1.9 ± 3.1 cm, p = 0.006), decreased net work about the knee (0.23 J/kg, p < 0.001) and no increase in ankle joint work ( p = 0.207), compared with jumping with no exoskeleton. Based on our findings, to mimic unassisted ankle joint moment profiles, a future bi-articular device would need increased elastic element slack length, greater stiffness and a larger moment arm about the ankle. Future designs could also employ attachment sites that have minimal overlying soft tissue, such as the pelvis, to improve comfort of the device.

Schlagwörter

Stichwörter der Autor:innen

assistive deviceelasticgastrocnemiussoft exoskeleton

Autor:innen und Institutionen

  • Department for Health, University of Bath, Bath, UK.
  • School of Human Movement and Nutrition Sciences, The University of Queensland, Brisbane, Queensland, Australia.
  • School of Exercise and Nutrition Sciences, Queensland University of Technology, Brisbane, Queensland, Australia.
  • Public Health & Sport Sciences, University of Exeter, Exeter, UK.

ORCID-Profile: Logan Wade, Glen Lichtwark, Dominic Farris

Förderung

  • Australian Government

Zitieren

APA

Wade, L., Lichtwark, G., & Farris, D. (2024). Implementation of a passive bi-articular ankle–knee exoskeleton during maximal squat jumping. Royal Society Open Science, 11(7). https://doi.org/10.1098/rsos.240390

Vancouver

Wade L, Lichtwark G, Farris D. Implementation of a passive bi-articular ankle–knee exoskeleton during maximal squat jumping. Royal Society Open Science. 2024;11(7). doi:10.1098/rsos.240390

BibTeX
@article{Wade2024,
  author = {Wade, Logan and Lichtwark, Glen and Farris, Dominic},
  title = {Implementation of a passive bi-articular ankle–knee exoskeleton during maximal squat jumping},
  journal = {Royal Society Open Science},
  year = {2024},
  volume = {11},
  number = {7},
  doi = {10.1098/rsos.240390}
}
Kostenlos starten →