EUVIMEDEuropean Health Evidence
Uhr 10/10Sources Journal Tree
Easy Demo

Lokaler Crossref-Datenbestand · journal-article

Comparison of lenticular scanning quality and visual outcomes of keratorefractive lenticule extraction between VisuMax 800 and 500 systems

Jiayi Hu, Yongle Bao, Zhanying Wang, Yiyang Wang, Junjie Yu, Yishan Qian, Xiaoying Wang, Xingtao Zhou, Jing Zhao

Journal of Cataract & Refractive Surgery · 2026

Vollständiger Abstract

Worum geht es in dieser Arbeit?

Purpose: To compare lenticular scanning quality and visual outcomes between keratorefractive lenticule extraction performed with VisuMax 800 and VisuMax 500 systems. Setting: Single ophthalmic surgical center. Design: Comparative, nonrandomized prospective study. Methods: Consecutive patients aged 18 to 46 years were recruited between November 2024 and March 2025. Opaque bubble layer (OBL) and lenticular surface regularity were measured using intraoperative imaging and scanning electron microscopy. Visual acuity and refractive error were assessed at 1 month, 3 months, and 6 months postoperatively. Results: A total of 140 participants (140 eyes) were included (70 per group). The VisuMax 800 group had significantly lower OBL proportions (3.97% ± 2.58% vs 2.44% ± 0.52%, P = .013) and better lenticular surface regularity scores (11.85 ± 2.56 vs 14.98 ± 4.05, P = .048). In the VisuMax 800 group, higher flat K and steep K correlated with larger OBL areas (β = 0.412, P < .001; β = 0.358, P = .002) and larger optical zones were associated with better lenticular surface regularity (β = 0.535, P = .038). No statistically significant difference was observed in the visual and refractive outcomes between the 2 groups at the 6-month postoperative follow-up ( P > .05). In the VisuMax 800 group, smaller OBL proportions were associated with better visual acuity at 1 and 3 months postoperatively (β < 0, P < .05), while better lenticular surface regularity was correlated with lower astigmatism at 3 months postoperatively (β = −0.574, P = .002). Conclusions: Although technical advancements of the VisuMax 800 may optimize intraoperative lenticular scanning quality, the VisuMax 800 and 500 systems yield comparable visual outcomes.

Bibliografischer Nachweis

Publikationsdaten

Autor:innen
Jiayi Hu, Yongle Bao, Zhanying Wang, Yiyang Wang, Junjie Yu, Yishan Qian, Xiaoying Wang, Xingtao Zhou, Jing Zhao
Quelle
Journal of Cataract & Refractive Surgery
Publikation
2026-01-01
Band / Ausgabe
Nicht angegeben
Seiten
Nicht angegeben
ISSN / ISBN
0886-3350, 1873-4502
Zitationen
1 laut Crossref
Referenzen
0 hinterlegt

Zitieren

Zitierfähiger Nachweis

Jiayi Hu, Yongle Bao, Zhanying Wang, Yiyang Wang, Junjie Yu, Yishan Qian, Xiaoying Wang, Xingtao Zhou, Jing Zhao (2026). Comparison of lenticular scanning quality and visual outcomes of keratorefractive lenticule extraction between VisuMax 800 and 500 systems. Journal of Cataract & Refractive Surgery. https://doi.org/10.1097/j.jcrs.0000000000001927
RIS BibTeX CSL-JSON

Kontext

Themen, Förderung und Nutzung

Lizenzhinweise: Lizenz 1