EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-SA 4.0

A novel lumen-apposing metal stent for endoscopic drainage of symptomatic pancreatic fluid collections: a retrospective study

Ning Xu, Longsong Li, Song Su, Danqi Zhao, Jingyuan Xiang, Pengju Wang, Yaxuan Cheng, Enqiang Linghu, Ningli Chai

Endoscopic Ultrasound · 2024-01 · 13 (1) · 40-45

DOI: 10.1097/eus.0000000000000039 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopic Ultrasound, online erschienen am 29.12.2023. Verfasst von Ning Xu und 8 weiteren Autor:innen. Beteiligte Einrichtung: Senior Department of Gastroenterology, the First Medical Center of PLA General Hospital, Beijing 100853, China. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Objectives Previous studies showed that lumen-apposing metal stent (LAMS) provides a feasible route to perform direct endoscopic necrosectomy. However, the high risk of bleeding and migration induced by the placement of LAMS attracted attention. The aim of this study was to evaluate the safety and effectiveness of a novel LAMS.

Methods

In this retrospective study, we enrolled patients with symptomatic pancreatic fluid collections (PFCs) to perform EUS–guided drainage with a LAMS in our hospital. Evaluation variables included technical success rate, clinical success rate, and adverse events.

Results

Thirty-two patients with a mean age of 41.38 ± 10.72 years (53.1% males) were included in our study, and the mean size of PFC was 10.06 ± 3.03 cm. Technical success rate and clinical success rate reached 96.9% and 93.8%, respectively. Stent migration occurred in 1 patient (3.1%), and no stent-induced bleeding occurred. The outcomes of using LAMS in 10 patients with pancreatic pseudocyst and 22 patients with walled-off necrosis were comparable. Compared with pancreatic pseudocyst, walled-off necrosis needed more direct endoscopic necrosectomy times to achieve resolution ( P = 0.024).

Conclusions

Our study showed that the novel LAMS is effective and safe for endoscopic drainage of PFCs with a relatively low rate of adverse events. Further large-scale multicenter studies are needed to confirm the present findings.

Schlagwörter

Stichwörter der Autor:innen

Direct endoscopic necrosectomyLumen-apposing metal stentsPancreatic fluid collectionsPseudocystWalled-off necrosis

Autor:innen und Institutionen

  • Senior Department of Gastroenterology, the First Medical Center of PLA General Hospital, Beijing 100853, China.

Zitieren

APA

Xu, N., Li, L., Su, S., Zhao, D., Xiang, J., Wang, P., Cheng, Y., Linghu, E., & Chai, N. (2024). A novel lumen-apposing metal stent for endoscopic drainage of symptomatic pancreatic fluid collections: a retrospective study. Endoscopic Ultrasound, 13(1), 40-45. https://doi.org/10.1097/eus.0000000000000039

Vancouver

Xu N, Li L, Su S, Zhao D, Xiang J, Wang P, et al. A novel lumen-apposing metal stent for endoscopic drainage of symptomatic pancreatic fluid collections: a retrospective study. Endoscopic Ultrasound. 2024;13(1):40-45. doi:10.1097/eus.0000000000000039

BibTeX
@article{Xu2024,
  author = {Xu, Ning and Li, Longsong and Su, Song and Zhao, Danqi and Xiang, Jingyuan and Wang, Pengju and Cheng, Yaxuan and Linghu, Enqiang and Chai, Ningli},
  title = {A novel lumen-apposing metal stent for endoscopic drainage of symptomatic pancreatic fluid collections: a retrospective study},
  journal = {Endoscopic Ultrasound},
  year = {2024},
  volume = {13},
  number = {1},
  pages = {40--45},
  doi = {10.1097/eus.0000000000000039}
}