A novel lumen-apposing metal stent for endoscopic drainage of symptomatic pancreatic fluid collections: a retrospective study
Endoscopic Ultrasound · 2024-01 · 13 (1) · 40-45
DOI: 10.1097/eus.0000000000000039 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopic Ultrasound, online erschienen am 29.12.2023. Verfasst von Ning Xu und 8 weiteren Autor:innen. Beteiligte Einrichtung: Senior Department of Gastroenterology, the First Medical Center of PLA General Hospital, Beijing 100853, China. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).
Abstract (Originalsprache)
Background and Objectives Previous studies showed that lumen-apposing metal stent (LAMS) provides a feasible route to perform direct endoscopic necrosectomy. However, the high risk of bleeding and migration induced by the placement of LAMS attracted attention. The aim of this study was to evaluate the safety and effectiveness of a novel LAMS.
Methods
In this retrospective study, we enrolled patients with symptomatic pancreatic fluid collections (PFCs) to perform EUS–guided drainage with a LAMS in our hospital. Evaluation variables included technical success rate, clinical success rate, and adverse events.
Results
Thirty-two patients with a mean age of 41.38 ± 10.72 years (53.1% males) were included in our study, and the mean size of PFC was 10.06 ± 3.03 cm. Technical success rate and clinical success rate reached 96.9% and 93.8%, respectively. Stent migration occurred in 1 patient (3.1%), and no stent-induced bleeding occurred. The outcomes of using LAMS in 10 patients with pancreatic pseudocyst and 22 patients with walled-off necrosis were comparable. Compared with pancreatic pseudocyst, walled-off necrosis needed more direct endoscopic necrosectomy times to achieve resolution ( P = 0.024).
Conclusions
Our study showed that the novel LAMS is effective and safe for endoscopic drainage of PFCs with a relatively low rate of adverse events. Further large-scale multicenter studies are needed to confirm the present findings.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Senior Department of Gastroenterology, the First Medical Center of PLA General Hospital, Beijing 100853, China.
Zitieren
APA
Xu, N., Li, L., Su, S., Zhao, D., Xiang, J., Wang, P., Cheng, Y., Linghu, E., & Chai, N. (2024). A novel lumen-apposing metal stent for endoscopic drainage of symptomatic pancreatic fluid collections: a retrospective study. Endoscopic Ultrasound, 13(1), 40-45. https://doi.org/10.1097/eus.0000000000000039
Vancouver
Xu N, Li L, Su S, Zhao D, Xiang J, Wang P, et al. A novel lumen-apposing metal stent for endoscopic drainage of symptomatic pancreatic fluid collections: a retrospective study. Endoscopic Ultrasound. 2024;13(1):40-45. doi:10.1097/eus.0000000000000039
BibTeX
@article{Xu2024,
author = {Xu, Ning and Li, Longsong and Su, Song and Zhao, Danqi and Xiang, Jingyuan and Wang, Pengju and Cheng, Yaxuan and Linghu, Enqiang and Chai, Ningli},
title = {A novel lumen-apposing metal stent for endoscopic drainage of symptomatic pancreatic fluid collections: a retrospective study},
journal = {Endoscopic Ultrasound},
year = {2024},
volume = {13},
number = {1},
pages = {40--45},
doi = {10.1097/eus.0000000000000039}
}