EUVIMEDEUVIMED entdecken
Systematische ÜbersichtMetaanalyse

Optimal timing for lumen-apposing metal stent removal following endoscopic ultrasound-guided drainage of pancreatic fluid collections: a systematic review and meta-analysis

Marcello Maida iD, Giacomo Emanuele Maria Rizzo iD, Mario Traina, John Gásdal Karstensen iD, Rogier P Voermans iD, Joan B Gornals iD, Nitin Jagtap iD, Dario Ligresti iD, Lucio Carrozza iD, Gabriele Rancatore, Marco Ventimiglia, Antonio Facciorusso iD und 4 weitere

Endoscopy · 01.09.2025 · 57 (09) · 1023-1033

DOI: 10.1055/a-2577-3814 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Endoscopy, erschienen am 01.09.2025. Verfasst von Marcello Maida und 15 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine and Surgery, University of Enna "Kore", Enna, Italy. Hauptthemen laut MEDLINE: Drainage, Device Removal, Stents, Pancreatic Pseudocyst. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 27 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Lumen-apposing metal stents (LAMSs) are widely used for endoscopic ultrasound (EUS)-guided drainage of pancreatic fluid collections (PFCs). Safety is a major concern and the timing of LAMS removal is debated owing to the risk of adverse events (AEs). Previous studies showed early stent removal was associated with a reduced risk of AEs, but data are still conflicting. The aim of this systematic review with meta-analysis was to identify the optimal timing for LAMS removal.

Methods

Major databases were systematically searched until May 2024. The outcome assessed was the cumulative incidence of AEs related to the early (within 3–4 weeks) versus late (after 3–4 weeks) removal of the LAMS. A random-effects (DerSimonian–Laird) model was used to pool the results.

Results

Eight studies (1820 patients; mean age 54–61.6 years; 63 % men) were included in the analysis. PFCs included walled-off necrosis (WON; 58.2 %) and pseudocysts (41.8 %). Pooled LAMS-related AEs rate were similar in the late versus early removal groups (risk ratio [RR] 1.03, 95 %CI 0.47–2.28; P = 0.94). Sensitivity analysis, including only studies applying a 4-week cut-off, confirmed a comparable AEs rate (RR 0.80, 95 %CI 0.38–1.65; P = 0.59). The mean (SD) follow-up of the studies was 208 (88) days.

Conclusions

The results of this meta-analysis showed no difference in the incidence of AEs between early and late removal of LAMSs in the presence of moderate heterogeneity across studies. Removal within 4 weeks is not warranted, and it may instead be planned on a clinical case-by-case basis according on the patient's condition.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

DrainageDevice RemovalStentsPancreatic PseudocystHumansEndosonographyTime FactorsUltrasonography, Interventional

Autor:innen und Institutionen

  • Department of Medicine and Surgery, University of Enna "Kore", Enna, Italy.
  • Gastroenterology Unit, Umberto I Hospital, Enna, Italy.
  • Gastroenterology and Endoscopy Unit, Department of Diagnostic and Therapeutic Services, Istituto mediterraneo per i trapianti e terapie ad alta specializzazione, IRCCS-ISMETT, Palermo, Italy.
  • Pancreatitis Centre East (PACE), Gastro Unit, Copenhagen University Hospital - Amager and Hvidovre, Hvidovre, Denmark.
  • Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark.
  • Department of Gastroenterology and Hepatology, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands.

ORCID-Profile: Marcello Maida, Giacomo Emanuele Maria Rizzo, John Gásdal Karstensen, Rogier P Voermans, Joan B Gornals, Nitin Jagtap, Dario Ligresti, Lucio Carrozza, Antonio Facciorusso, Ilaria Tarantino

Zitieren

APA

Maida, M., Rizzo, G. E. M., Traina, M., Karstensen, J. G., Voermans, R. P., Gornals, J. B., Jagtap, N., Ligresti, D., Carrozza, L., Rancatore, G., Ventimiglia, M., Facciorusso, A., Fabbri, C., Anderloni, A., Tarantino, I., & I-EUS group (2025). Optimal timing for lumen-apposing metal stent removal following endoscopic ultrasound-guided drainage of pancreatic fluid collections: a systematic review and meta-analysis. Endoscopy, 57(09), 1023-1033. https://doi.org/10.1055/a-2577-3814

Vancouver

Maida M, Rizzo GEM, Traina M, Karstensen JG, Voermans RP, Gornals JB, et al. Optimal timing for lumen-apposing metal stent removal following endoscopic ultrasound-guided drainage of pancreatic fluid collections: a systematic review and meta-analysis. Endoscopy. 2025;57(09):1023-1033. doi:10.1055/a-2577-3814

BibTeX
@article{Maida2025,
  author = {Maida, Marcello and Rizzo, Giacomo Emanuele Maria and Traina, Mario and Karstensen, John Gásdal and Voermans, Rogier P and Gornals, Joan B and Jagtap, Nitin and Ligresti, Dario and Carrozza, Lucio and Rancatore, Gabriele and Ventimiglia, Marco and Facciorusso, Antonio and Fabbri, Carlo and Anderloni, Andrea and Tarantino, Ilaria and I-EUS group, I-EUS group},
  title = {Optimal timing for lumen-apposing metal stent removal following endoscopic ultrasound-guided drainage of pancreatic fluid collections: a systematic review and meta-analysis},
  journal = {Endoscopy},
  year = {2025},
  volume = {57},
  number = {09},
  pages = {1023--1033},
  doi = {10.1055/a-2577-3814}
}
Kostenlos starten →