EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Design of modified flattening filter for International Organization for Standardization recommended 147Pm beta source: a Monte Carlo approach

Sujoy Chatterjee, Rolf Behrens iD, Rohit Yadav iD, Ashok K Bakshi, Balvinder K Sapra

Radiation Protection Dosimetry · 08.09.2026

DOI: 10.1093/rpd/ncag108 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, online erschienen am 08.09.2026. Verfasst von Sujoy Chatterjee und 4 weiteren Autor:innen. Beteiligte Einrichtung: RP&AD, Variable Energy Cyclotron Centre, Kolkata, 700064, India. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A modified beam-flattening filter design for the 147Pm beta source of the irradiation facility Beta Secondary Standard BSS-2 has been developed to achieve substantially improved dose-rate uniformity, targeting ±5% or better over the required phantom area. The study was performed using the Monte Carlo simulation codes EGSnrc and PHITS. The proposed filter design demonstrates a significant enhancement in dose-rate homogeneity at a calibration distance of 20 cm compared with the existing International Organization for Standardization (ISO)-recommended filter (ISO 6980 standard series). The dose-rate uniformity improved from approximately ±8% to nearly ±1% within a circular region of radius 7.5 cm, while simultaneously increasing the absolute central dose-rate by ~30%.

Autor:innen und Institutionen

  • RP&AD, Variable Energy Cyclotron Centre, Kolkata, 700064, India.
  • Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, Braunschweig, 38116, Germany.
  • RP&AD, Bhabha Atomic Research Centre, Mumbai, 400094, India.

ORCID-Profile: Rolf Behrens, Rohit Yadav

Zitieren

APA

Chatterjee, S., Behrens, R., Yadav, R., Bakshi, A. K., & Sapra, B. K. (2026). Design of modified flattening filter for International Organization for Standardization recommended 147Pm beta source: a Monte Carlo approach. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncag108

Vancouver

Chatterjee S, Behrens R, Yadav R, Bakshi AK, Sapra BK. Design of modified flattening filter for International Organization for Standardization recommended 147Pm beta source: a Monte Carlo approach. Radiation Protection Dosimetry. 2026. doi:10.1093/rpd/ncag108

BibTeX
@article{Chatterjee2026,
  author = {Chatterjee, Sujoy and Behrens, Rolf and Yadav, Rohit and Bakshi, Ashok K and Sapra, Balvinder K},
  title = {Design of modified flattening filter for International Organization for Standardization recommended 147Pm beta source: a Monte Carlo approach},
  journal = {Radiation Protection Dosimetry},
  year = {2026},
  doi = {10.1093/rpd/ncag108}
}
Kostenlos starten →