EUVIMEDEUVIMED entdecken
Crossref

Assessment of weight-based variations in effective dose for common PET/CT scans in a tertiary hospital

Abdallah T Al Said iD, Azhar A Rahman, Laith K Albadarneh iD, Ammar A Oglat, Fatin N Binti A Halim, Wesal Firas, Yahia Alshloul, Khaldoon M Radaideh

Radiation Protection Dosimetry · 02.11.2026 · 202 (18) · 1477-1485

DOI: 10.1093/rpd/ncag078 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, online erschienen am 06.08.2026. Verfasst von Abdallah T Al Said und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Physics, Universiti Sains Malaysia, 11800 USM Minden, Penang, Malaysia. Hauptthemen laut MEDLINE: Positron Emission Tomography Computed Tomography, Radiation Dosage, Body Weight. Die Arbeit nennt 28 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Positron Emission Tomography/Computed Tomography (PET/CT) is a crucial imaging modality widely used for diagnosing and staging various cancers. Although patient weight is known to influence radiation dose, there is limited research on optimizing PET/CT protocols based on weight categories to minimize unnecessary exposure.

Objectives

This study evaluates the effective dose for common PET/CT scans at Penang Hospital, with a particular focus on the influence of patient weight on both PET and CT dose components. Additionally, the study assesses whether weight-based dose protocols can contribute to dose optimization.

Methods

This retrospective study analyzed 1439 PET/CT scans performed at Penang Hospital. The effective dose was calculated using International Commission on Radiological Protection (ICRP) 103, 106, and 128 dose coefficients. Conversion factors used were 0.019 mSv/MBq for 18F-FDG, 0.0199 mSv/MBq for 68Ga-PSMA, and 0.021 mSv/MBq for 68Ga-DOTATATE. The CT dose component was estimated using the dose-length product (DLP) with an empirical conversion factor (k = 0.015 mSv·mGy−1·cm−1) for whole-body CT.

Results

The total effective dose for 18F-FDG (head-to-thigh and head-to-feet) scans was 12.34 and 16.38 mSv, respectively. For 68Ga-PSMA and 68Ga-DOTATATE scans, the total effective dose was 11.55 and 12.00 mSv, respectively. A statistically significant increase in dose was observed in heavier patients due to increased administered activity and CT parameters (P < .05). Weight had a smaller impact on PET dose in 68Ga-PSMA and 68Ga-DOTATATE compared to 18F-FDG.

Conclusion

Patient weight significantly influences the total effective dose in PET/CT examinations. These findings highlight the importance of considering patient-specific factors when evaluating radiation dose in clinical practice.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Positron Emission Tomography Computed TomographyRadiation DosageBody WeightHumansRetrospective StudiesTertiary Care CentersFluorodeoxyglucose F18FemaleMaleOrganometallic CompoundsMiddle AgedAgedAdultRadiopharmaceuticalsAged, 80 and over

Substanzen

Fluorodeoxyglucose F18Organometallic CompoundsRadiopharmaceuticalsgallium Ga 68 dotatate

Autor:innen und Institutionen

  • School of Physics, Universiti Sains Malaysia, 11800 USM Minden, Penang, Malaysia.
  • Department of Medical Radiologic Technologies, Faculty of Applied Medical Sciences, Al Al-Bayt University, Mafraq, Jordan.
  • Department of Medical Imaging, Faculty of Applied Medical Sciences, The Hashemite University, Zarqa 13133, Jordan.
  • Department of Nuclear Medicine, Penang General Hospital, Penang, Malaysia.
  • Department of Medical Physics, Faculty of Sciences, Yarmouk University, Irbid 21163, Jordan.
  • Princess Basma Teaching Hospital, Ministry of Health, P.O. Box 9, Irbid 21110, Jordan.

ORCID-Profile: Abdallah T Al Said, Laith K Albadarneh

Zitieren

APA

Al Said, A. T., Rahman, A. A., Albadarneh, L. K., Oglat, A. A., Binti A Halim, F. N., Firas, W., Alshloul, Y., & Radaideh, K. M. (2026). Assessment of weight-based variations in effective dose for common PET/CT scans in a tertiary hospital. Radiation Protection Dosimetry, 202(18), 1477-1485. https://doi.org/10.1093/rpd/ncag078

Vancouver

Al Said AT, Rahman AA, Albadarneh LK, Oglat AA, Binti A Halim FN, Firas W, et al. Assessment of weight-based variations in effective dose for common PET/CT scans in a tertiary hospital. Radiation Protection Dosimetry. 2026;202(18):1477-1485. doi:10.1093/rpd/ncag078

BibTeX
@article{AlSaid2026,
  author = {Al Said, Abdallah T and Rahman, Azhar A and Albadarneh, Laith K and Oglat, Ammar A and Binti A Halim, Fatin N and Firas, Wesal and Alshloul, Yahia and Radaideh, Khaldoon M},
  title = {Assessment of weight-based variations in effective dose for common PET/CT scans in a tertiary hospital},
  journal = {Radiation Protection Dosimetry},
  year = {2026},
  volume = {202},
  number = {18},
  pages = {1477--1485},
  doi = {10.1093/rpd/ncag078}
}
Kostenlos starten →