Experimental estimation of extremity doses from handheld XRF devices during radiation exposure incidents
Radiation Protection Dosimetry · 2026
DOI: 10.1093/rpd/ncag075 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2026. Verfasst von M Kowatari und 4 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Radiological Sciences, National Institutes for Quantum Science and Technology, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, Japan. Hauptthemen laut MEDLINE: Radiation Monitoring, Spectrometry, X-Ray Emission, Radiation Protection, Radiation Exposure. Die Arbeit nennt 15 Literaturangaben. Gefördert von: Hojokin, Ministry of Health, Labour and Welfare, Japan.
Abstract (Originalsprache)
This study experimentally evaluates extremity doses from unintentional exposure emitted by handheld X-ray fluorescence (XRF) analyzers. Although handheld XRF devices are widely used for material analysis, quantitative assessments of unintentional exposure remain limited. Mockup experiments were conducted using a Thermo Scientific NITON XLt 797 analyzer and a polymethyl methacrylate hand phantom equipped with radiophotoluminescent glass dosemeters (GD-302M). Spectrometric measurements were performed with a CdTe detector, and photon fluence spectra were unfolded using the MAXED code with Particle and Heavy Ion Transport code System-generated response functions. The mean X-ray energy was 28.4 ± 0.03 keV, with characteristic molybdenum peaks at ~17.5 keV (Kα) and 19.6 keV (Kβ). For a typical 30-s analysis, the estimated personal dose equivalent Hp(0.07) at the point of contact was ~95 μSv. The Hp(0.07) on the dorsal side was roughly one-fifth of the palmar dose. Ambient dose equivalent rates measured directly from the XRF device may reach high enough to set radiation-controlled areas, underscoring the need for strict handling protocols. These findings demonstrate the importance of radiological protection education and awareness when using handheld XRF devices.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Institute of Radiological Sciences, National Institutes for Quantum Science and Technology, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, Japan.
- Physical Measurement Technology Group, Tokyo Metropolitan Industrial Technology Research Institute, 2-4-10 Aomi, Koto, 135-064 Tokyo, Japan.
- Department of Radiation Protection, Nuclear Science Research Institute, Japan Atomic Energy Agency, 2-4, Shirakata, Tokai, Naka, Ibaraki 319-1195, Japan.
ORCID-Profile: M Kowatari, T Tsuji, Y Tanimura
Förderung
- Hojokin
- Ministry of Health, Labour and Welfare, Japan
Zitieren
APA
Kowatari, M., Kataoka, N., Kobayashi, M., Tsuji, T., & Tanimura, Y. (2026). Experimental estimation of extremity doses from handheld XRF devices during radiation exposure incidents. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncag075
Vancouver
Kowatari M, Kataoka N, Kobayashi M, Tsuji T, Tanimura Y. Experimental estimation of extremity doses from handheld XRF devices during radiation exposure incidents. Radiation Protection Dosimetry. 2026. doi:10.1093/rpd/ncag075
BibTeX
@article{Kowatari2026,
author = {Kowatari, M and Kataoka, N and Kobayashi, M and Tsuji, T and Tanimura, Y},
title = {Experimental estimation of extremity doses from handheld XRF devices during radiation exposure incidents},
journal = {Radiation Protection Dosimetry},
year = {2026},
doi = {10.1093/rpd/ncag075}
}